This section describes how to calculate the leak rate of a vacuum-decay leak verification, which is described in § 1065.345(e) . Use the following equation to calculate the leak rate,, and compare it to the criterion specified in § 1065.345(e) :
Eq. 1065.644-1
Where:
Vvac = geometric volume of the vacuum-side of the sampling system.
R = molar gas constant.
p2 = vacuum-side absolute pressure at time t2.
T2 = vacuum-side absolute temperature at time t2.
p1 = vacuum-side absolute pressure at time t1.
T1 = vacuum-side absolute temperature at time t1.
t2 = time at completion of vacuum-decay leak verification test.
t1 = time at start of vacuum-decay leak verification test.
Example:
Vvac
R = 8.314472 J/(mol·K) = 8.314472 (m2·kg)/(s2·mol·K)
p2
t2
p1
T1
t2
= 10:56:25 a.m.
40 C.F.R. §1065.644