40 C.F.R. § 1042 app II to Part 1042

Current through October 31, 2024
Appendix II to Part 1042 - Steady-State Duty Cycles

(a) The following duty cycles apply as specified in § 1042.505(b)(1) :

(1) The following duty cycle applies for discrete-mode testing:

E3 mode No.Engine speed1 Percent of
maximum
test power
Weighting
factors
1Maximum test speed1000.2
291%750.5
380%500.15
463%250.15

1 Maximum test speed is defined in 40 CFR part 1065. Percent speed values are relative to maximum test speed.

(2) The following duty cycle applies for ramped-modal testing:

RMC
mode
Time in mode
(seconds)
Engine
speed1 3
Power
(percent)2 3
1a Steady-state229Maximum test speed100%.
1b Transition20Linear transitionLinear transition in torque.
2a Steady-state16663%25%.
2b Transition20Linear transitionLinear transition in torque.
3a Steady-state57091%75%.
3b Transition20Linear transitionLinear transition in torque.
4a Steady-state17580%50%.

1 Maximum test speed is defined in 40 CFR part 1065. Percent speed is relative to maximum test speed.

2 The percent power is relative to the maximum test power.

3 Advance from one mode to the next within a 20 second transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode, and simultaneously command a similar linear progression for engine speed if there is a change in speed setting.

(b) The following duty cycles apply as specified in § 1042.505(b)(2) :

(1) The following duty cycle applies for discrete-mode testing:

E5 mode No.Engine
speed1
Percent of
maximum
test power
Weighting
factors
1Maximum test speed1000.08
291%750.13
380%500.17
463%250.32
5Warm idle00.3

1 Maximum test speed is defined in 40 CFR part 1065. Percent speed values are relative to maximum test speed.

(2) The following duty cycle applies for ramped-modal testing:

RMC
mode
Time in mode
(seconds)
Engine
speed1 3
Power
(percent)2 3
1a Steady-state167Warm idle0.
1b Transition20Linear transitionLinear transition in torque.
2a Steady-state85Maximum test speed100%.
2b Transition20Linear transitionLinear transition in torque.
3a Steady-state35463%25%.
3b Transition20Linear transitionLinear transition in torque.
4a Steady-state14191%75%.
4b Transition20Linear transitionLinear transition in torque.
5a Steady-state18280%50%.
5b Transition20Linear transitionLinear transition in torque.
6 Steady-state171Warm idle0.

1 Maximum test speed is defined in 40 CFR part 1065. Percent speed is relative to maximum test speed.

2 The percent power is relative to the maximum test power.

3 Advance from one mode to the next within a 20 second transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode, and simultaneously command a similar linear progression for engine speed if there is a change in speed setting.

(c) The following duty cycles apply as specified in § 1042.505(b)(3) :

(1) The following duty cycle applies for discrete-mode testing:

E2 mode No.Engine
speed1
Torque
(percent)2
Weighting
factors
1Engine Governed1000.2
2Engine Governed750.5
3Engine Governed500.15
4Engine Governed250.15

1 Speed terms are defined in 40 CFR part 1065.

2 The percent torque is relative to the maximum test torque as defined in 40 CFR part 1065.

(2) The following duty cycle applies for ramped-modal testing:

RMC modeTime in mode
(seconds)
Engine speedTorque
(percent)1 2
1a Steady-state229Engine Governed100%.
1b Transition20Engine GovernedLinear transition.
2a Steady-state166Engine Governed25%.
2b Transition20Engine GovernedLinear transition.
3a Steady-state570Engine Governed75%.
3b Transition20Engine GovernedLinear transition.
4a Steady-state175Engine Governed50%.

1 The percent torque is relative to the maximum test torque as defined in 40 CFR part 1065.

2 Advance from one mode to the next within a 20 second transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode.

40 C.F.R. 1042 app II to Part 1042

81 FR 74156 , Oct. 25, 2016