The following standards, which EPA originally adopted under 40 CFR part 89, apply to nonroad compression-ignition engines produced before the model years specified in § 1039.1 :
(a) Tier 1 standards apply as summarized in the following table:
Table 1 to Appendix I-Tier 1 Emission Standards
[g/kW-hr]
Rated power (kW) | Starting model year | NOX | HC | NOX + NMHC | CO | PM |
kW[LESS THAN] 8 | 2000 | 10.5 | 8.0 | 1.0 | ||
8 [LESS THAN EQUAL TO] kW [LESS THAN] 19 | 2000 | 9.5 | 6.6 | 0.80 | ||
19 [LESS THAN EQUAL TO] kW [LESS THAN] 37 | 1999 | 9.5 | 5.5 | 0.80 | ||
37 [LESS THAN EQUAL TO] kW [LESS THAN] 75 | 1998 | 9.2 | ||||
75 [LESS THAN EQUAL TO] kW [LESS THAN] 130 | 1997 | 9.2 | ||||
130 [LESS THAN EQUAL TO] kW [LESS THAN EQUAL TO] 560 | 1996 | 9.2 | 1.3 | 11.4 | 0.54 | |
kW [GREATER THAN] 560 | 2000 | 9.2 | 1.3 | 11.4 | 0.54 |
(b) Tier 2 standards apply as summarized in the following table:
Table 2 to Appendix I-Tier 2 Emission Standards
[g/kW-hr]
Rated power (kW) | Starting model year | NOX + NMHC | CO | PM |
kW[LESS THAN] 8 | 2005 | 7.5 | 8.0 | 0.80 |
8 [LESS THAN EQUAL TO] kW [LESS THAN] 19 | 2005 | 7.5 | 6.6 | 0.80 |
19 [LESS THAN EQUAL TO] kW [LESS THAN] 37 | 2004 | 7.5 | 5.5 | 0.60 |
37 [LESS THAN EQUAL TO] kW [LESS THAN] 75 | 2004 | 7.5 | 5.0 | 0.40 |
75 [LESS THAN EQUAL TO] kW [LESS THAN] 130 | 2003 | 6.6 | 5.0 | 0.30 |
130 [LESS THAN EQUAL TO] kW [LESS THAN] 225 | 2003 | 6.6 | 3.5 | 0.20 |
225 [LESS THAN EQUAL TO] kW [LESS THAN] 450 | 2001 | 6.4 | 3.5 | 0.20 |
450 [LESS THAN EQUAL TO] kW [LESS THAN EQUAL TO] 560 | 2002 | 6.4 | 3.5 | 0.20 |
kW [GREATER THAN] 560 | 2006 | 6.4 | 3.5 | 0.20 |
(c) Tier 3 standards apply as summarized in the following table:
Table 3 to Appendix I-Tier 3 Emission Standards
[g/kW-hr]
Rated power (kW) | Starting model year | NOX+NMHC | CO | PM |
37 [LESS THAN EQUAL TO] kW [LESS THAN] 75 | 2008 | 4.7 | 5.0 | 0.40 |
75 [LESS THAN EQUAL TO] kW [LESS THAN] 130 | 2007 | 4.0 | 5.0 | 0.30 |
130 [LESS THAN EQUAL TO] kW [LESS THAN EQUAL TO] 560 | 2006 | 4.0 | 3.5 | 0.20 |
(d) Tier 1 through Tier 3 standards applied only for discrete-mode steady-state testing. There were no not-to-exceed standards or transient testing.
40 C.F.R. 1039 app I to Part 1039