40 C.F.R. § 445.11

Current through September 30, 2024
Section 445.11 - Effluent limitations attainable by the application of the best practicable control technology currently available (BPT)

Except as provided in 40 CFR 125.30 through 125.32 , any existing point source subject to this subpart must achieve the following effluent limitations which represent the application of BPT:

Effluent Limitations

Regulated parameter Maximum daily1 Maximum monthly avg.1
BOD522056
TSS8827
Ammonia (as N)104.9
[ALPHA]-Terpineol0.0420.019
Aniline0.0240.015
Benzoic acid0.1190.073
Naphthalene0.0590.022
p-Cresol0.0240.015
Phenol0.0480.029
Pyridine0.0720.025
Arsenic1.10.54
Chromium1.10.46
Zinc0.5350.296
pH(2)(2)

1 Milligrams per liter (mg/L, ppm).

2 Within the range 6 to 9.

40 C.F.R. §445.11

65 FR 3048, Jan. 19, 2000; 65 FR 14344, Mar. 16, 2000