Except as provided in subpart L of this part and 40 CFR 125.30 through 125.32 , any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable after application of the best practicable control technology currently available (BPT):
Effluent characteristic | Effluent limitations | |
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Milligrams per liter | ||
TSS | 30 | 20 |
Fe | 2.0 | 1.0 |
pH | (1) | (1) |
1 Within the range 6.0 to 9.0.
Effluent characteristic | Effluent limitations | |
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Milligrams per liter | ||
TSS | 30 | 20 |
Zn | 1.0 | .5 |
Ni | .2 | .1 |
pH | (1) | (1) |
1 Within the range 6.0 to 9.0.
Effluent characteristic | Effluent limitations | |
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Milligrams per liter | ||
TSS | 30 | 20 |
Fe | 2 | 1 |
pH | (1) | (1) |
1 Within the range 6.0 to 9.0.
40 C.F.R. § 440.52