Section 434.42 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT)

Except as provided in 40 CFR 125.30-125.32 , 40 CFR 401.17 , and §§ 434.61 and 434.63 of this part, the following limitations establish the concentration or quality of pollutants which may be discharged by a point source subject to the provisions of this subpart after application of the best practicable control technology currently available:

BPT Effluent Limitations

Pollutant or pollutant property Maximum for any 1 day Average of daily values for 30 consecutive days
Concentration in mg/l
Iron, total7.03.5
TSS70.35.
pH(1)(1)

1 Within the range 6.0 to 9.0 at all times.