40 C.F.R. § 430.106

Current through September 30, 2024
Section 430.106 - Pretreatment standards for existing sources (PSES)

Except as provided in 40 CFR 403.7 and 403.13 , any existing source subject to this subpart that introduces pollutants into a publicly owned treatment works must: Comply with 40 CFR part 403 ; and achieve the following pretreatment standards for existing sources (PSES) if it uses chlorophenolic-containing biocides. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using these biocides. PSES must be attained on or before July 1, 1984:

Subpart J

[PSES for secondary fiber non-deink facilities where paperboard from wastepaper is produced]

Pollutant or pollutant propertyMaximum for any 1 day
Milligrams/liter (mg/l) Kg/kkg (or pounds per 1,000 lb) of producta
Pentachlorophenol(0.032)(7.2)/y0.00096
Trichlorophenol(0.010)(7.2)/y0.00030
y = wastewater discharged in kgal per ton of product.

a The following equivalent mass limitations are provided as guidance in cases when POTWs find it necessary to impose mass effluent limitations.

Subpart J

[PSES for secondary fiber non-deink facilities where builders' paper and roofing felt from wastepaper are produced]

Pollutant or pollutant propertyMaximum for any 1 day
Milligrams/liter (mg/l) Kg/kkg (or pounds per 1,000 lb) of producta
Pentachlorophenol(0.032)(14.4)y0.0019
Trichlorophenol(0.010)(14.4)y0.00060
y = wastewater discharged in kgal per ton of product.

a The following equivalent mass limitations are provided as guidance in cases when POTWs find it necessary to impose mass effluent limitations.

Subpart J

[PSES for secondary fiber non-deink facilities where tissue from wastepaper is produced without deinking]

Pollutant or pollutant propertyMaximum for any 1 day
Milligrams/liter (mg/l) Kg/kkg (or pounds per 1,000 lb) of producta
Pentachlorophenol(0.032)(25.2)y0.0034
Trichlorophenol(0.010)(25.2)/y0.0011
y = wastewater discharged in kgal per ton of product.

a The following equivalent mass limitations are provided as guidance in cases when POTWs find it necessary to impose mass effluent limitations.

Subpart J

[PSES for secondary fiber non-deink facilities where molded products from wastepaper are produced without deinking]

Pollutant or pollutant propertyMaximum for any 1 day
Milligrams/liter (mg/l) Kg/kkg (or pounds per 1,000 lb) of producta
Pentachlorophenol(0.032)(21.1)y0.0028
Trichlorophenol(0.010)(21.1)y0.00088
y = wastewater discharged in kgal per ton of product.

a The following equivalent mass limitations are provided as guidance in cases when POTWs find it necessary to impose mass effluent limitations.

40 C.F.R. §430.106