40 C.F.R. § 428.116

Current through October 31, 2024
Section 428.116 - Pretreatment standards for new sources

Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403 . In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart:

Pollutant or pollutant property Pretreatment standards
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed-
Metric units (kg/kkg of raw material)
Zinc0.0580.024
BOD5(1)(1)
TSS(1)(1)
pH(1)(1)
English units (lb/1,000 lb of raw material)
Zinc0.0580.024
BOD5(1)(1)
TSS(1)(1)
pH(1)(1)

1 No limitation.

40 C.F.R. §428.116

40 FR 2345, Jan. 10, 1975, as amended at 60 FR 33964, June 29, 1995