40 C.F.R. § 421.146

Current through November 30, 2024
Section 421.146 - Pretreatment standards for new sources

Except as provided in 40 CFR 403.7 , any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources. The mass of wastewater pollutants in primary antimony process wastewater introduced into a POTW shall not exceed the following values:

(a) Sodium Antimonate Autoclave Wastewater.

PSNS for the Primary Antimony Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of antimony contained in sodium antimonate product
Antimony30.15013.440
Arsenic21.7209.687
Mercury2.3440.937

(b) Fouled Anolyte.

PSNS for the Primary Antimony Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of antimony metal produced by electrowinning
Antimony30.15013.440
Arsenic21.7209.687
Mercury2.3440.937

(c) Cathode Antimony Washwater.

PSNS for the Primary Antimony Subcategory

Pollutant or pollutant property Maximum for any 1 day Maximum for monthly average
mg/kg (pounds per million pounds) of antimony metal produced by electrowinning
Antimony60.31026.870
Arsenic43.43019.370
Mercury4.6871.875

40 C.F.R. §421.146