40 C.F.R. § 421.52

Current through October 31, 2024
Section 421.52 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available

Except as provided in 40 CFR 125.30 through 125.32 , any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Effluent Limitations

Effluent characteristic Maximum for any 1 day Average of Daily values for 30 consecutive days shall not exceed
(Metric units, kg/kkg of product; English units, pounds per 1,000 lb of product)
Total suspended solids0.1000.050
Copper0.00170.0008
Cadmium0.000060.00003
Lead0.00060.0026
Zinc0.00120.0003
pH(1)(1)

1 Within the range of 6.0 to 9.0.

40 C.F.R. §421.52