Except as provided in 40 CFR 125.30 through 125.32 , any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional technology.
Subpart L
Pollutant or pollutant property | BCT effluent limitations | |
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg/kkg (pounds per 1,000 lb) of product | ||
TSS | 0.175 | 0.0751 |
O&G | 0.0751 | 0.0250 |
pH | (1) | (1) |
1 Within the range of 6.0 to 9.0.
Subpart L
Pollutant or pollutant property | BCT effluent limitations | |
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kg/kkg (pounds per 1,000 lb) of product | ||
TSS | 0.701 | 0.300 |
O&G | 0.300 | 0.100 |
pH | (1) | (1) |
1 Within the range of 6.0 to 9.0.
Subpart LBAT Effluent Limitations
Pollutant or pollutant property | BCT effluent limitations | |
Maximum for any 1 day | Average of daily values for 30 consecutive days | |
Kilograms per day | ||
TSS | 38.1 | 16.3 |
O&G | 16.3 | 5.45 |
pH | (1) | (1) |
1 Within the range of 6.0 to 9.0.
The above limitations shall be applicable to each fume scrubber associated with any of the coating operations specified above.
40 C.F.R. §420.127