40 C.F.R. § 420.122

Current through September 30, 2024
Section 420.122 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT)

Except as provided in 40 CFR 125.30 through 125.32 , any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

(a)Galvanizing, terne coating, and other coatings -
(1)Strip, sheet, and miscellaneous products.

Subpart L

Pollutant or pollutant propertyBPT effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
TSS0.1750.0751
O&G0.07510.0250
Lead0.001130.000376
Zinc0.001500.000500
Chromium (hexavalent)10.0001500.0000501
pH(2)(2)

1 The limitations for hexavalent chromium shall apply only to galvanizing operations which discharge wastewaters from the chromate rinse step.

2 Within the range of 6.0 to 9.0.

(2) [Reserved]
(b)Galvanizing and other coatings -
(1)Wire products and fasteners.

Subpart L

Pollutant or pollutant propertyBPT effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg/kkg (pounds per 1,000 lb) of product
TSS0.7010.300
O&G0.3000.100
Lead0.004510.00150
Zinc0.006010.00200
Chromium (hexavalent)10.0006000.000200
pH(2)(2)

1 The limitations for hexavalent chromium shall be applicable only to galvanizing operations which discharge wastewaters from the chromate rinse step.

2 Within the range of 6.0 to 9.0.

(2) [Reserved]
(c)Fume scrubbers.

Subpart L

Pollutant or pollutant propertyBPT effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days
Kg per day
TSS38.116.3
O&G16.35.45
Lead0.2450.0819
Zinc0.3270.109
Chromium (hexavalent)10.03270.0109
pH(2)(2)

1 The limitations for hexavalent chromium shall be applicable only to galvanizing operations which discharge wastewaters from the chromate rinse step.

2 Within the range of 6.0 to 9.0.

The above limitations shall be applicable to each fume scrubber associated with any of the coating operations specified above.

40 C.F.R. §420.122

47 FR 23284, May 27, 1982; 47 FR 41739, Sept. 22, 1982, as amended at 49 FR 21036, May 17, 1984