40 C.F.R. § 417.115

Current through October 31, 2024
Section 417.115 - Standards of performance for new sources

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

Effluent characteristicEffluent limitations
Maximum for any 1 dayAverage of daily values for 30 consecutive days shall not exceed-
Metric units (kilograms per 1,000 kg of anhydrous product)
BOD50.200.10
COD0.90.45
TSS0.02.01
Surfactants0.20.10
Oil and grease0.04.02
pH(1)(1)
English units (pounds per 1,000 lb of anhydrous product)
BOD50.200.10
COD0.90.45
TSS0.02.01
Surfactants0.20.10
Oil and grease0.04.02
pH(1)(1)

1 Within the range 6.0 to 9.0.

40 C.F.R. § 417.115