40 C.F.R. § 408.267

Current through October 31, 2024
Section 408.267 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology

Except as provided in §§ 125.30 through 125.32 , the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology:

Effluent characteristicEffluent limitations
Maximum for any 1 day Average of daily values for thirty consecutive days shall not exceed-
Metric units (kilograms per 1,000 kg of product)
TSS2316
Oil and grease1.10.77
pH(1)(1)
English units (pounds per 1,000 lb of product)
TSS2316
Oil and grease1.10.77
pH(1)(1)

1 Within the range 6.0 to 9.0.

40 C.F.R. §408.267

51 FR 24998, July 9, 1986