40 C.F.R. § 408.295

Current through October 31, 2024
Section 408.295 - Standards of performance for new sources
(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
(1) Any Alaskan scallop processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:

Effluent characteristicEffluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed-
Metric units (kg/kkg of product)
TSS5.71.4
Oil and grease7.30.23
pH(1)(1)
English units (lb/1,000 lb of product)
TSS5.71.4
Oil and grease7.30.23
pH(1)(1)

1 Within the range 6.0 to 9.0.

(2) Any Alaskan scallop processing facility not covered under § 408.295(a) (1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.
(b) [Reserved]

40 C.F.R. §408.295