40 C.F.R. § Table W-1 to Subpart W of Part 98

Current through October 31, 2024
Appendix Table W-1 to Subpart W of Part 98 - [Effective 1/1/2025] Default Whole Gas Population Emission Factors

Industry segment Source type/componentEmission factor (scf whole gas/ hour/unit)
Population Emission Factors-Pneumatic Device Vents and Pneumatic Pumps, Gas Service1
. Onshore petroleum and natural gas productionContinuous Low Bleed Pneumatic Device Vents 26.8
. Onshore petroleum and natural gas gathering and boostingContinuous High Bleed Pneumatic Device Vents 221
Intermittent Bleed Pneumatic Device Vents 28.8
Pneumatic Pumps 313.3
. Onshore natural gas processingContinuous Low Bleed Pneumatic Device Vents 26.8
. Onshore natural gas transmission compressionContinuous High Bleed Pneumatic Device Vents 230
. Underground natural gas storageIntermittent Bleed Pneumatic Device Vents 22.3
. Natural gas distribution
Population Emission Factors-Major Equipment, Gas Service1
. Onshore petroleum and natural gas productionWellhead8.87
. Onshore petroleum and natural gas gathering and boostingSeparator9.65
Meters/Piping7.04
Compressor13.8
Dehydrator8.09
Heater5.22
Storage Vessel1.83
Population Emission Factors-Major Equipment, Crude Service
Onshore petroleum and natural gas productionWellhead4.13
Separator4.77
Meters/Piping12.4
Compressor13.8
Dehydrator8.09
Heater3.2
Storage Vessel1.91
Population Emission Factors-Gathering Pipelines, by Material Type4
Onshore petroleum and natural gas gathering and boostingProtected Steel0.93
Unprotected Steel8.2
Plastic/Composite0.28
Cast Iron8.4

1 For multi-phase flow that includes gas, use the gas service emission factors.

2 Emission factor is in units of "scf whole gas/hour/device."

3 Emission factor is in units of "scf whole gas/hour/pump."

4 Emission factors are in units of "scf whole gas/hour/mile of pipeline."

40 C.F.R. §Table W-1 to Subpart W of Part 98