Where:
ProcesstypeEi = Annual emissions of input gas i from the process type on a fab basis (metric tons).
Eij = Annual emissions of input gas i from process sub-type or process type j as calculated in Equation I-8 of this subpart (metric tons).
N = The total number of process sub-types j that depends on the electronics manufacturing fab and emission calculation methodology. If Eij is calculated for a process type j in Equation I-8 of this subpart, N = 1.
i = Input gas.
j = Process sub-type or process type.
Where:
ProcesstypeBEk = Annual emissions of by-product gas k from the processes type on a fab basis (metric tons).
BEijk = Annual emissions of by-product gas k formed from input gas i used for process sub-type or process type j as calculated in Equation I-9 of this subpart (metric tons).
N = The total number of process sub-types j that depends on the electronics manufacturing fab and emission calculation methodology. If BEijk is calculated for a process type j in Equation I-9 of this subpart, N = 1.
i = Input gas.
j = Process sub-type, or process type.
k = By-product gas.
Where:
Eij = Annual emissions of input gas i from process sub-type or process type j, on a fab basis (metric tons).
Cij = Amount of input gas i consumed for process sub-type or process type j, as calculated in Equation I-13 of this subpart, on a fab basis (kg).
Uij = Process utilization rate for input gas i for process sub-type or process type j (expressed as a decimal fraction).
aij = Fraction of input gas i used in process sub-type or process type j with abatement systems, on a fab basis (expressed as a decimal fraction).
dij = Fraction of input gas i destroyed or removed in abatement systems connected to process tools where process sub-type, or process type j is used, on a fab basis (expressed as a decimal fraction). This is zero unless the facility adheres to the requirements in § 98.94(f) .
UTij = The average uptime factor of all abatement systems connected to process tools in the fab using input gas i in process sub-type or process type j, as calculated in Equation I-15 of this subpart, on a fab basis (expressed as a decimal fraction).
0.001 = Conversion factor from kg to metric tons.
i = Input gas.
j = Process sub-type or process type.
Where:
BEijk = Annual emissions of by-product gas k formed from input gas i from process sub-type or process type j, on a fab basis (metric tons).
Bijk = By-product formation rate of gas k created as a by-product per amount of input gas i (kg) consumed by process sub-type or process type j (kg).
Cij = Amount of input gas i consumed for process sub-type, or process type j, as calculated in Equation I-13 of this subpart, on a fab basis (kg).
aij = Fraction of input gas i used for process sub-type, or process type j with abatement systems, on a fab basis (expressed as a decimal fraction).
djk = Fraction of by-product gas k destroyed or removed in abatement systems connected to process tools where process sub-type, or process type j is used, on a fab basis (expressed as a decimal fraction). This is zero unless the facility adheres to the requirements in § 98.94(f) .
UTijk = The average uptime factor of all abatement systems connected to process tools in the fab emitting by-product gas k, formed from input gas i in process sub-type or process type j, on a fab basis (expressed as a decimal fraction). For this equation, UTijk is assumed to be equal to UTij as calculated in Equation I-15 of this subpart.
0.001 = Conversion factor from kg to metric tons.
i = Input gas.
j = Process sub-type or process type.
k = By-product gas.
Where:
E(N2O)j = Annual emissions of N2O for N2O-using process j, on a fab basis (metric tons).
CN2O,j = Amount of N2O consumed for N2O-using process j, as calculated in Equation I-13 of this subpart and apportioned to N2O process j, on a fab basis (kg).
UN2O,j = Process utilization factor for N2O-using process j (expressed as a decimal fraction) from Table I-8 of this subpart.
aN2O,j = Fraction of N2O used in N2O-using process j with abatement systems, on a fab basis (expressed as a decimal fraction).
dN2O,j = Fraction of N2O for N2O-using process j destroyed or removed in abatement systems connected to process tools where process j is used, on a fab basis (expressed as a decimal fraction). This is zero unless the facility adheres to the requirements in § 98.94(f) .
UTN2O = The average uptime factor of all the abatement systems connected to process tools in the fab that use N2O, as calculated in Equation I-15 of this subpart, on a fab basis (expressed as a decimal fraction). For purposes of calculating the abatement system uptime for N2O using process tools, in Equation I-15 of this subpart, the only input gas i is N2O, j is the N2O using process, and p is the N2O abatement system connected to the N2O using tool.
0.001 = Conversion factor from kg to metric tons.
j = Type of N2O-using process, either chemical vapor deposition or all other N2O-using manufacturing processes.
where:
Ci = Annual consumption of input gas i, on a fab basis (kg per year).
IBi = Inventory of input gas i stored in containers at the beginning of the reporting year, including heels, on a fab basis (kg). For containers in service at the beginning of a reporting year, account for the quantity in these containers as if they were full.
IEi = Inventory of input gas i stored in containers at the end of the reporting year, including heels, on a fab basis (kg). For containers in service at the end of a reporting year, account for the quantity in these containers as if they were full.
Ai = Acquisitions of input gas i during the year through purchases or other transactions, including heels in containers returned to the electronics manufacturing facility, on a fab basis (kg).
Di = Disbursements of input gas i through sales or other transactions during the year, including heels in containers returned by the electronics manufacturing facility to the chemical supplier, as calculated using Equation I-12 of this subpart, on a fab basis (kg).
i = Input gas.
where:
Di = Disbursements of input gas i through sales or other transactions during the reporting year on a fab basis, including heels in containers returned by the electronics manufacturing fab to the gas distributor (kg).
hil = Fab-wide gas-specific heel factor for input gas i and container size and type l (expressed as a decimal fraction), as determined in § 98.94(b) . If your fab uses less than 50 kg of a fluorinated GHG or N2O in one reporting year, you may assume that any hil for that fluorinated GHG or N2O is equal to zero.
Nil = Number of containers of size and type l used at the fab and returned to the gas distributor containing the standard heel of input gas i.
Fil = Full capacity of containers of size and type l containing input gas i (kg).
Xi = Disbursements under exceptional circumstances of input gas i through sales or other transactions during the year, on a fab basis (kg). These include returns of containers whose contents have been weighed due to an exceptional circumstance as specified in § 98.94(b)(4) .
i = Input gas.
l = Size and type of gas container.
M = The total number of different sized container types on a fab basis. If only one size and container type is used for an input gas i, M = 1.
where:
Ci,j = The annual amount of input gas i consumed, on a fab basis, for process sub-type or process type j (kg).
fi,j = Process sub-type-specific or process type-specific j, input gas i apportioning factor (expressed as a decimal fraction), as determined in accordance with § 98.94(c) .
Ci = Annual consumption of input gas i, on a fab basis, as calculated using Equation I-11 of this subpart (kg).
i = Input gas.
j = Process sub-type or process type.
Where:
UTij = The average uptime factor of all abatement systems connected to process tools in the fab using input gas i in process sub-type or process type j (expressed as a decimal fraction).
Tdijp = The total time, in minutes, that abatement system p, connected to process tool(s) in the fab using input gas i in process sub-type or process type j, is not in operational mode, as defined in § 98.98 , when at least one of the tools connected to abatement system p is in operation.
UTijp = Total time, in minutes per year, in which abatement system p has at least one associated tool in operation. For determining the amount of tool operating time, you may assume that tools that were installed for the whole of the year were operated for 525,600 minutes per year. For tools that were installed or uninstalled during the year, you must prorate the operating time to account for the days in which the tool was not installed; treat any partial day that a tool was installed as a full day (1,440 minutes) of tool operation. For an abatement system that has more than one connected tool, the tool operating time is 525,600 minutes per year if at least one tool was installed at all times throughout the year. If you have tools that are idle with no gas flow through the tool for part of the year, you may calculate total tool time using the actual time that gas is flowing through the tool.
i = Input gas.
j = Process sub-type or process type.
p = Abatement system.
where:
EHi = Emissions of fluorinated heat transfer fluid i, on a fab basis (metric tons/year).
Densityi = Density of fluorinated heat transfer fluid i (kg/l).
IiB = Inventory of fluorinated heat transfer fluid i, on a fab basis, in containers other than equipment at the beginning of the reporting year (in stock or storage) (l). The inventory at the beginning of the reporting year must be the same as the inventory at the end of the previous reporting year.
Pi = Acquisitions of fluorinated heat transfer fluid i, on a fab basis, during the reporting year (l), including amounts purchased from chemical suppliers, amounts purchased from equipment suppliers with or inside of equipment, and amounts returned to the facility after off-site recycling.
Ni = Total nameplate capacity (full and proper charge) of equipment that uses fluorinated heat transfer fluid i and that is newly installed in the fab during the reporting year (l).
Ri = Total nameplate capacity (full and proper charge) of equipment that uses fluorinated heat transfer fluid i and that is removed from service in the fab during the reporting year (l).
IiE = Inventory of fluorinated heat transfer fluid i, on a fab basis, in containers other than equipment at the end of the reporting year (in stock or storage) (l). The inventory at the beginning of the reporting year must be the same as the inventory at the end of the previous reporting year.
Di = Disbursements of fluorinated heat transfer fluid i, on a fab basis, during the reporting year, including amounts returned to chemical suppliers, sold with or inside of equipment, and sent off-site for verifiable recycling or destruction (l). Disbursements should include only amounts that are properly stored and transported so as to prevent emissions in transit.
0.001 = Conversion factor from kg to metric tons.
i = Fluorinated heat transfer fluid.
Where:
Eis = Total fluorinated GHG input gas i, emitted from stack system s, during the sampling period (kg).
Xism = Average concentration of fluorinated GHG input gas i in stack system s, during the time interval m (ppbv).
MWi = Molecular weight of fluorinated GHG input gas i (g/g-mole).
Qs = Flow rate of the stack system s, during the sampling period (m3/min).
SV = Standard molar volume of gas (0.0240 m3/g-mole at 68 °F and 1 atm).
[DELTA]tm = Length of time interval m (minutes). Each time interval in the FTIR sampling period must be less than or equal to 60 minutes (for example an 8 hour sampling period would consist of at least 8 time intervals).
1/103 = Conversion factor (1 kilogram/1,000 grams).
i = Fluorinated GHG input gas.
s = Stack system.
N = Total number of time intervals m in sampling period.
m = Time interval.
Where:
Eks = Total fluorinated GHG by-product gas k, emitted from stack system s, during the sampling period (kg).
Xks = Average concentration of fluorinated GHG by-product gas k in stack system s, during the time interval m (ppbv).
MWk = Molecular weight of the fluorinated GHG by-product gas k (g/g-mole).
Qs = Flow rate of the stack system s, during the sampling period (m3/min).
SV = Standard molar volume of gas (0.0240 m3/g-mole at 68 °F and 1 atm).
[DELTA]tm = Length of time interval m (minutes). Each time interval in the FTIR sampling period must be less than or equal to 60 minutes (for example an 8 hour sampling period would consist of at least 8 time intervals).
1/103 = Conversion factor (1 kilogram/1,000 grams).
k = Fluorinated GHG by-product gas.
s = Stack system.
N = Total number of time intervals m in sampling period.
m = Time interval.
Where:
EFif = Emission factor for fluorinated GHG input gas i, from fab f, representing 100 percent abatement system uptime (kg emitted/kg input gas consumed).
Eis = Mass emission of fluorinated GHG input gas i from stack system s, during the sampling period (kg emitted).
Activityif = Consumption of fluorinated GHG input gas i, for fab f, in the tools vented to the stack systems being tested, during the sampling period, as determined following the procedures specified in § 98.94(j)(3) (kg consumed).
UTf = The total uptime of all abatement systems for fab f, during the sampling period, as calculated in Equation I-23 of this subpart (expressed as decimal fraction). If the stack system does not have abatement systems on the tools vented to the stack system, the value of this parameter is zero.
aif = Fraction of fluorinated GHG input gas i used in fab f in tools with abatement systems (expressed as a decimal fraction).
dif = Fraction of fluorinated GHG input gas i destroyed or removed in abatement systems connected to process tools in fab f, as calculated in Equation I-24A of this subpart (expressed as decimal fraction). If the stack system does not have abatement systems on the tools vented to the stack system, the value of this parameter is zero.
f = Fab.
i = Fluorinated GHG input gas.
s = Stack system.
Where:
EFkf = Emission factor for fluorinated GHG by-product gas k, from fab f, representing 100 percent abatement system uptime (kg emitted/kg of all input gases consumed in tools vented to stack systems that are tested).
Eks = Mass emission of fluorinated GHG by-product gas k, emitted from stack system s, during the sampling period (kg emitted).
Activityif = Consumption of fluorinated GHG input gas i for fab f in tools vented to stack systems that are tested, during the sampling period as determined following the procedures specified in § 98.94(j)(3) (kg consumed).
UTf = The total uptime of all abatement systems for fab f, during the sampling period, as calculated in Equation I-23 of this subpart (expressed as decimal fraction).
af = Fraction of all fluorinated input gases used in fab f in tools with abatement systems (expressed as a decimal fraction).
dkf = Fraction of fluorinated GHG by-product gas k destroyed or removed in abatement systems connected to process tools in fab f, as calculated in Equation I-24B of this subpart (expressed as decimal fraction).
f = Fab.
i = Fluorinated GHG input gas.
k = Fluorinated GHG by-product gas.
s = Stack system.
Where:
Eif = Annual emissions of fluorinated GHG input gas i (kg/year) from the stack systems that are tested for fab f.
EFif = Emission factor for fluorinated GHG input gas i emitted from fab f, as calculated in Equation I-19 of this subpart (kg emitted/kg input gas consumed).
Cif = Total consumption of fluorinated GHG input gas i in tools that are vented to stack systems that are tested, for fab f, for the reporting year, as calculated using Equation I-13 of this subpart (kg/year).
UTf = The total uptime of all abatement systems for fab f, during the reporting year, as calculated using Equation I-23 of this subpart (expressed as a decimal fraction).
aif = Fraction of fluorinated GHG input gas i used in fab f in tools with abatement systems (expressed as a decimal fraction).
dif = Fraction of fluorinated GHG input gas i destroyed or removed in abatement systems connected to process tools in fab f that are included in the stack testing option, as calculated in Equation I-24A of this subpart (expressed as decimal fraction).
f = Fab.
i = Fluorinated GHG input gas.
Where:
Ekf = Annual emissions of fluorinated GHG by-product k (kg/year) from the stack systems that are tested for fab f.
EFkf = Emission factor for fluorinated GHG by-product k, emitted from fab f, as calculated in Equation I-20 of this subpart (kg emitted/kg of all fluorinated input gases consumed).
Cif = Total consumption of fluorinated GHG input gas i in tools that are vented to stack systems that are tested, for fab f, for the reporting year, as calculated using Equation I-13 of this subpart.
UTf = The total uptime of all abatement systems for fab f, during the reporting year as calculated using Equation I-23 of this subpart (expressed as a decimal fraction).
af = Fraction of fluorinated input gases used in fab f in tools with abatement systems (expressed as a decimal fraction).
dkf = Fraction of fluorinated GHG by-product k destroyed or removed in abatement systems connected to process tools in fab f that are included in the stack testing option, as calculated in Equation I-24B of this subpart (expressed as decimal fraction).
f = Fab.
i = Fluorinated GHG input gas.
k = Fluorinated GHG by-product
Where:
UTf = The average uptime factor for all abatement systems in fab f (expressed as a decimal fraction).
Tdpf = The total time, in minutes, that abatement system p, connected to process tool(s) in fab f, is not in operational mode as defined in § 98.98 .
UTpf = Total time, in minutes per year, in which the tool(s) connected at any point during the year to abatement system p, in fab f could be in operation. For determining the amount of tool operating time, you may assume that tools that were installed for the whole of the year were operated for 525,600 minutes per year. For tools that were installed or uninstalled during the year, you must prorate the operating time to account for the days in which the tool was not installed; treat any partial day that a tool was installed as a full day (1,440 minutes) of tool operation. For an abatement system that has more than one connected tool, the tool operating time is 525,600 minutes per year if there was at least one tool installed at all times throughout the year. If you have tools that are idle with no gas flow through the tool, you may calculate total tool time using the actual time that gas is flowing through the tool.
f = Fab.
p = Abatement system.
Where:
dif = The average weighted fraction of fluorinated GHG input gas i destroyed or removed in abatement systems in fab f (expressed as a decimal fraction).
dkf = The average weighted fraction of fluorinated GHG by-product gas k destroyed or removed in abatement systems in fab f (expressed as a decimal fraction).
Cijf = The amount of fluorinated GHG input gas i consumed for process type or sub-type j fed into abatement systems in fab f as calculated using Equation I-13 of this subpart (kg).
(1-Uij) = The default emission factor for input gas i used in process type or sub-type j, from applicable Tables I-3 through I-7 of this subpart.
Bijk = The default byproduct gas formation rate factor for by-product gas k from input gas i used in process type or sub-type j, from applicable Tables I-3 through I-7 of this subpart.
DREij = Destruction or removal efficiency for fluorinated GHG input gas i in abatement systems connected to process tools where process type or sub-type j is used (expressed as a decimal fraction) determined according to § 98.94(f) .
DREjk = Destruction or removal efficiency for fluorinated GHG by-product gas k in abatement systems connected to process tools where input gas i is used in process type or sub-type j (expressed as a decimal fraction) determined according to § 98.94(f) .
f = fab.
i = Fluorinated GHG input gas.
j = Process type or sub-type.
40 C.F.R. §98.93