Where:
ECPViACTUAL = Emissions from each Group 1 continuous process vent i subject to § 63.1315 that is uncontrolled or is controlled to a level less stringent than the applicable reference control technology. ECPViACTUAL is calculated according to paragraph (g)(2) of this section.
(0.02)ECPViu = Emissions from each Group 1 continuous process vent i subject to § 63.1315 if the applicable reference control technology had been applied to the uncontrolled emissions. ECPViu is calculated according to paragraph (g)(2) of this section.
ECPVSjACTUAL = Emissions from Group 1 continuous process vents subject to § 63.1316(b)(1)(i), (b)(1)(ii), (b)(2)(i), (b)(2)(ii), or (c)(1) located in the collection of process sections j within the affected source that are uncontrolled or controlled to a level less stringent than the applicable standard. ECPVSjACTUAL is calculated according to paragraph (g)(3) of this section.
ECPVSjSTD = Emissions from Group 1 continuous process vents subject to § 63.1316(b)(1)(i), (b)(1)(ii), (b)(2)(i), (b)(2)(ii), or (c)(1) located in the collection of process sections j within the affected source if the applicable standard had been applied to the uncontrolled emissions. ECPVSjSTD is calculated according to paragraph (g)(3) of this section.
ESiACTUAL = Emissions from each Group 1 storage vessel i that is uncontrolled or is controlled to a level less stringent than the applicable reference control technology or standard. ESiACTUAL is calculated according to paragraph (g)(4) of this section.
(BL)ESiu = Emissions from each Group 1 storage vessel i if the applicable reference control technology or standard had been applied to the uncontrolled emissions. ESiu is calculated according to paragraph (g)(4) of this section. For calculating emissions, BL = 0.05 for each Group 1 storage vessel i subject to § 63.1314(a) ; and BL = 0.02 for each storage vessel i subject to § 63.1314(c) .
EWWiACTUAL = Emissions from each Group 1 wastewater stream i that is uncontrolled or is controlled to a level less stringent than the applicable reference control technology. EWWiACTUAL is calculated according to paragraph (g)(5) of this section.
EWWic = Emissions from each Group 1 wastewater stream i if the reference control technology had been applied to the uncontrolled emissions. EWWic is calculated according to paragraph (g)(5) of this section.
EBPViACTUAL = Emissions from each Group 1 batch process vent i that is uncontrolled or is controlled to a level less stringent than the applicable standard. EBPVACTUAL is calculated according to paragraph (g)(6) of this section.
(0.10)EBPViu = Emissions from each Group 1 batch process vent i if the applicable standard had been applied to the uncontrolled emissions. EBPViu is calculated according to paragraph (g)(6) of this section.
EABViACTUAL = Emissions from each Group 1 aggregate batch vent stream i that is uncontrolled or is controlled to a level less stringent than the applicable standard. EABPViACTUAL is calculated according to paragraph (g)(7) of this section.
(0.10)EABViu = Emissions from each Group 1 aggregate batch vent stream i if the applicable standard had been applied to the uncontrolled emissions. EABViu is calculated according to paragraph (g)(7) of this section.
n = The number of emission points being included in the emissions average.
Where:
ECPViu = Uncontrolled continuous process vent emission rate from continuous process vent i, megagrams per month.
Q = Vent stream flow rate, dry standard cubic meters per minute, measured using Method 2, 2A, 2C, or 2D, 40 CFR part 60, appendix A, as appropriate.
h = Monthly hours of operation during which positive flow is present in the continuous process vent, hours per month.
Cj = Concentration, parts per million by volume, dry basis, of organic HAP j as measured by Method 18, 40 CFR part 60, appendix A.
Mj = Molecular weight of organic HAP j, gram per gram-mole.
n = Number of organic HAP in stream.
Where:
ECPVSjstd = Emissions if the applicable standard had been applied to the uncontrolled emissions, megagrams per month.
EFstd = 0.000018 Mg organic HAP/Mg of product, if the collection of process sections within the affected source is subject to § 63.1316(b)(1)(i) .
= 0.00002 Mg organic HAP/Mg of product, if the collection of process sections within the affected source is subject to § 63.1316(b)(1)(ii) or (b)(2)(ii) .
= 0.00004 Mg organic HAP/Mg of product, if the collection of process sections within the affected source is subject to § 63.1316(b)(2)(i) .
= 0.0000036 Mg organic HAP/Mg of product, if the collection of process sections within the affected source is subject to § 63.1316(c)(1) .
PPj = Polymer produced, Mg/month, for the collection of process sections j within the affected source, as calculated according to paragraph (g)(3)(ii)(B) of this section.
Where:
EABViu = Uncontrolled aggregate batch vent stream emission rate from aggregate batch vent stream i, megagrams per month.
Q = Vent stream flow rate, dry standard cubic meters per minute, measured using Method 2, 2A, 2C, or 2D, 40 CFR part 60, appendix A, as appropriate.
h = Monthly hours of operation during which positive flow is present from the aggregate batch vent stream, hours per month.
Cj = Concentration, parts per million by volume, dry basis, of organic HAP j as measured by Method 18, 40 CFR part 60, appendix A.
Mj = Molecular weight of organic HAP j, gram per gram-mole.
n = Number of organic HAP in the stream.
Where:
D = Discount factor = 0.9 for all credit generating emission points except those controlled by a pollution prevention measure; discount factor = 1.0 for each credit generating emission point controlled by a pollution prevention measure (i.e., no discount provided).
ECPV1iACTUAL = Emissions for each Group 1 continuous process vent i subject to § 63.1315 that is controlled to a level more stringent than the reference control technology. ECPV1iACTUAL is calculated according to paragraph (h)(2) of this section.
(0.02)ECPV1iu = Emissions from each Group 1 continuous process vent i subject to § 63.1315 if the applicable reference control technology had been applied to the uncontrolled emissions. ECPV1iu is calculated according to paragraph (h)(2) of this section.
ECPVS1jSTD = Emissions from Group 1 continuous process vents subject to § 63.1316(b)(1)(i), (b)(1)(ii), (b)(2)(i), (b)(2)(ii), or (c)(1) located in the collection of process sections j within the affected source if the applicable standard had been applied to the uncontrolled emissions. ECPVS1jSTD is calculated according to paragraph (h)(3) of this section.
ECPVS1jACTUAL = Emissions from Group 1 continuous process vents subject to § 63.1316(b)(1)(i), (b)(1)(ii), (b)(2)(i), (b)(2)(ii), or (c)(1) located in the collection of process sections j within the affected source that are controlled to a level more stringent than the applicable standard. ECPVS1jACTUAL is calculated according to paragraph (h)(3) of this section.
ECPV2iACTUAL = Emissions from each Group 2 continuous process vent i subject to § 63.1315 that is controlled. ECPV2iACTUAL is calculated according to paragraph (h)(2) of this section.
ECPV2iBASE = Emissions from each Group 2 continuous process vent i subject to § 63.1315 at the baseline date. ECPV2iBASE is calculated according to paragraph (h)(2) of this section.
ECPVS2jBASE = Emissions from Group 2 continuous process vents subject to § 63.1316(b)(1)(i) located in the collection of material recovery sections j within the affected source at the baseline date. ECPVS2jBASE is calculated according to paragraph (h)(3) of this section.
ECPVS2jACTUAL = Emissions from Group 2 continuous process vents subject to § 63.1316(b)(1)(i) located in the collection of material recovery sections j within the affected source that are controlled. ECPVS2jACTUAL is calculated according to paragraph (h)(3) of this section.
ES1iACTUAL = Emissions from each Group 1 storage vessel i that is controlled to a level more stringent than the applicable reference control technology or standard. ES1iACTUAL is calculated according to paragraph (h)(4) of this section.
(BL)ES1iu = Emissions from each Group 1 storage vessel i if the applicable reference control technology or standard had been applied to the uncontrolled emissions. ES1iu is calculated according to paragraph (h)(4) of this section. For calculating these emissions, BL = 0.05 for each Group 1 storage vessel i subject to § 63.1314(a) ; and BL = 0.02 for each storage vessel i subject to § 63.1314(c) .
ES2iACTUAL = Emissions from each Group 2 storage vessel i that is controlled. ES2iACTUAL is calculated according to paragraph (h)(4) of this section.
ES2iBASE = Emissions from each Group 2 storage vessel i at the baseline date. ES2iBASE is calculated according to paragraph (h)(4) of this section.
EWW1iACTUAL = Emissions from each Group 1 wastewater stream i that is controlled to a level more stringent than the reference control technology. EWW1iACTUAL is calculated according to paragraph (h)(5) of this section.
EWW1ic = Emissions from each Group 1 wastewater stream i if the reference control technology had been applied to the uncontrolled emissions. EWW1ic is calculated according to paragraph (h)(5) of this section.
EWW2iACTUAL = Emissions from each Group 2 wastewater stream i that is controlled. EWW2iACTUAL is calculated according to paragraph (h)(5) of this section.
EWW2iBASE = Emissions from each Group 2 wastewater stream i at the baseline date. EWW2iBASE is calculated according to paragraph (h)(5) of this section.
(0.10)EBPV1iu = Emissions from each Group 1 batch process vent i if the applicable standard had been applied to the uncontrolled emissions. EBPV1iu is calculated according to paragraph (h)(6) of this section.
EBPV1iACTUAL = Emissions from each Group 1 batch process vent i that is controlled to a level more stringent than the applicable standard. EBPV1iACTUAL is calculated according to paragraph (h)(6) of this section.
(0.10)EABV1iu = Emissions from each Group 1 aggregate batch vent stream i if the applicable standard had been applied to the uncontrolled emissions. EABV1iu is calculated according to paragraph (h)(7) of this section.
EABV1iACTUAL = Emissions from each Group 1 aggregate batch vent stream i that is controlled to a level more stringent than the applicable standard. EABV1iACTUAL is calculated according to paragraph (h)(7) of this section.
EBPV2iBASE = Emissions from each Group 2 batch process vent i at the baseline date. EBPV2iBASE is calculated according to paragraph (h)(6) of this section.
EBPV2iACTUAL = Emissions from each Group 2 batch process vent i that is controlled. EBPV2iACTUAL is calculated according to paragraph (h)(6) of this section.
EABV2iBASE = Emissions from each Group 2 aggregate batch vent stream i at the baseline date. EABV2iBASE is calculated according to paragraph (h)(7) of this section.
EABV2iACTUAL = Emissions from each Group 2 aggregate batch vent stream i that is controlled. EABV2iACTUAL is calculated according to paragraph (h)(7) of this section.
n = Number of Group 1 emission points included in the emissions average. The value of n is not necessarily the same for continuous process vents, batch process vents, aggregate batch vent streams, storage vessels, wastewater streams, or the collection of process sections within the affected source.
m = Number of Group 2 emission points included in the emissions average. The value of m is not necessarily the same for continuous process vents, batch process vents, aggregate batch vent streams, storage vessels, wastewater streams, or the collection of process sections within the affected source.
Where:
Percent reduction = Efficiency of pollution prevention measure (percent organic HAP reduction).
EB = Monthly emissions before the pollution prevention measure, megagrams per month, determined as specified in paragraphs (j)(2)(ii)(A), (j)(2)(ii)(B), and (j)(2)(ii)(C) of this section.
Epp = Monthly emissions after the pollution prevention measure, megagrams per month, as determined for the most recent month, determined as specified in either paragraphs (j)(2)(ii)(D) or (j)(2)(ii)(E) of this section.
PB = Monthly production before the pollution prevention measure, megagrams per month, during the same period over which EB is calculated.
Ppp = Monthly production after the pollution prevention measure, megagrams per month, as determined for the most recent month.
Where:
n = Number of wastewater streams.
QBi = Annual average flow rate for wastewater stream i before the pollution prevention measure, defined and determined according to § 63.144(c)(3) , liters per minute, before implementation of the pollution prevention measure.
HBi = Number of hours per month that wastewater stream i was discharged before the pollution prevention measure, hours per month.
s = Total number of organic HAP in wastewater stream i.
Fem = Fraction emitted of organic HAP m in wastewater from Table 34 of subpart G of this part, dimensionless.
HAPBim = Annual average concentration of organic HAP m in wastewater stream i, defined and determined according to paragraph § 63.150(g)(5)(i) of this section, before the pollution prevention measure, parts per million by weight, as measured before the implementation of the pollution measure.
40 C.F.R. §63.1332