As stated in § 63.7940 , you must comply with the applicable General Provisions requirements according to the following table:
Citation | Subject | Brief description | Applies to subpart GGGGG |
§ 63.1 | Applicability | Initial Applicability Determination; Applicability After Standard Established; Permit Requirements; Extensions, Notifications | Yes. |
§ 63.2 | Definitions | Definitions for part 63 standards | Yes. |
§ 63.3 | Units and Abbreviations | Units and abbreviations for part 63 standards | Yes. |
§ 63.4 | Prohibited Activities | Prohibited Activities; Compliance date; Circumvention, Severability | Yes. |
§ 63.5 | Construction/Reconstruction | Applicability; applications; approvals | Yes. |
§ 63.6(a) | Applicability | General Provisions (GP) apply unless compliance extension GP apply to area sources that become major | Yes. |
§ 63.6(b)(1)-(4) | Compliance Dates for New and Reconstructed sources | Standards apply at effective date; 3 years after effective date; upon startup; 10 years after construction or reconstruction commences for 112(f) | Yes. |
§ 63.6(b)(5) | Notification | Must notify if commenced construction or reconstruction after proposal | Yes. |
§ 63.6(b)(6) | [Reserved] | ||
§ 63.6(b)(7) | Compliance Dates for New and Reconstructed Area Sources That Become Major | Area sources that become major must comply with major source standards immediately upon becoming major, regardless of whether required to comply when they were an area source | Yes. |
§ 63.6(c)(1)-(2) | Compliance Dates for Existing Sources | Comply according to date in subpart, which must be no later than 3 years after effective date. For 112(f) standards, comply within 90 days of effective date unless compliance extension | Yes. |
§ 63.6(c)(3)-(4) | [Reserved] | ||
§ 63.6(c)(5) | Compliance Dates for Existing Area Sources That Become Major | Area sources that become major must comply with major source standards by date indicated in subpart or by equivalent time period (for example, 3 years) | Yes. |
§ 63.6(d) | [Reserved] | ||
§ 63.6(e)(1)-(2) | Operation & Maintenance | No, see § 63.7935(b) . | |
§ 63.6(e)(3) | Startup, Shutdown, and Malfunction Plan (SSMP) | No, see § 63.7935(c) . | |
§ 63.6(f)(1) | Compliance Except During SSM | No, see § 63.7935(b) . | |
§ 63.6(f)(2)-(3) | Methods for Determining Compliance | Compliance based on performance test, operation and maintenance plans, records, inspection | Yes. |
§ 63.6(g)(1)-(3) | Alternative Standard | Procedures for getting an alternative standard | Yes. |
§ 63.6(h) | Opacity/Visible Emissions (VE) Standards | Requirements for opacity and visible emissions limits | No. No opacity standards. |
§ 63.6(i)(1)-(14) | Compliance Extension | Procedures and criteria for Administrator to grant compliance extension | Yes. |
§ 63.6(j) | Presidential Compliance Exemption | President may exempt source category from requirement to comply with final rule | Yes. |
§ 63.7(a)(1)-(2) | Performance Test Dates | Dates for Conducting Initial Performance Testing and Other Compliance Demonstrations. Must conduct 180 days after first subject to final rule | Yes. |
§ 63.7(a)(3) | CAA Section 114 Authority | Administrator may require a performance test under CAA section 114 at any time | Yes. |
§ 63.7(b)(1) | Notification of Performance Test | Must notify Administrator 60 days before the test | Yes. |
§ 63.7(b)(2) | Notification of Rescheduling | If rescheduling a performance test is necessary, must notify Administrator 5 days before scheduled date of rescheduled date | Yes. |
§ 63.7(c) | Quality Assurance/Test Plan | Requirement to submit site-specific test plan 60 days before the test or on date Administrator agrees with: Test plan approval procedures; performance audit requirements; internal and external QA procedures for testing | Yes. |
§ 63.7(d) | Testing Facilities | Requirements for testing facilities | Yes. |
§ 63.7(e)(1) | Conditions for Conducting Performance Tests | Performance tests must be conducted under representative conditions. Cannot conduct performance tests during SSM. Not a violation to exceed standard during SSM | No, see § 63.7941(b)(2) . |
§ 63.7(e)(2) | Conditions for Conducting Performance Tests | Must conduct according to rule and EPA test methods unless Administrator approves alternative | Yes. |
§ 63.7(e)(3) | Test Run Duration | Must have three test runs of at least one hour each. Compliance is based on arithmetic mean of three runs. Conditions when data from an additional test run can be used | Yes. |
§ 63.7(f) | Alternative Test Method | Procedures by which Administrator can grant approval to use an alternative test method | Yes. |
§ 63.7(g) | Performance Test Data Analysis | Must include raw data in performance test report. Must submit performance test data 60 days after end of test with the Notification of Compliance Status. Keep data for 5 years | Yes. |
§ 63.7(h) | Waiver of Tests | Procedures for Administrator to waive performance test | Yes. |
§ 63.8(a)(1) | Applicability of Monitoring Requirements | Subject to all monitoring requirements in standard | Yes. |
§ 63.8(a)(2) | Performance Specifications | Performance Specifications in appendix B of part 60 apply | Yes. |
§ 63.8(a)(3) | [Reserved] | ||
§ 63.8(a)(4) | Monitoring with Flares | Unless your rule says otherwise, the requirements for flares in 63.11 apply | Yes. |
§ 63.8(b)(1) | Monitoring | Must conduct monitoring according to standard unless Administrator approves alternative | Yes. |
§ 63.8(b)(2)-(3) | Multiple Effluents and Multiple Monitoring Systems | Specific requirements for installing monitoring systems. Must install on each effluent before it is combined and before it is released to the atmosphere unless Administrator approves otherwise. If more than one monitoring system on an emissions point, must report all monitoring system results, unless one monitoring system is a backup | Yes. |
§ 63.8(c)(1) | Monitoring System Operation and Maintenance | Maintain monitoring system in a manner consistent with good air pollution control practices | Yes. |
§ 63.8(c)(1)(i) | Monitoring System Operation | Operate and maintain system as specified in § 63.6(e)(1) | No, see § 63.7935(b) . |
§ 63.8(c)(1)(ii) | Monitoring System Repair | Keep part for routine repairs available | Yes. |
§ 63.8(c)(1)(iii) | Monitoring System SSM Plan | Develop an SSM Plan for the monitoring system | No, see § 63.7935(h)(1) . |
§ 63.8(c)(2)-(3) | Monitoring System Installation | Must install to get representative emissions and parameter measurements. Must verify operational status before or at performance test | Yes. |
§ 63.8(c)(4) | Continuous Monitoring System (CMS) Requirements | CMS must be operating except during breakdown, out-of-control, repair, maintenance, and high-level calibration drifts | No. |
§ 63.8(c)(4)(i)-(ii) | Continuous Monitoring System (CMS) Requirements | COMS must have a minimum of one cycle of sampling and analysis for each successive 10-second period and one cycle of data recording for each successive 6-minute period. CEMS must have a minimum of one cycle of operation for each successive 15-minute period | Yes. However, COMS are not applicable. Requirements for CPMS are listed in §§ 63.7900 and 63.7913 . |
§ 63.8(c)(5) | COMS Minimum Procedures | COMS minimum procedures | No. |
§ 63.8(c)(6) | CMS Requirements | Zero and High level calibration check requirements | Yes. However requirements for CPMS are addressed in § 63.7927 . |
§ 63.8(c)(7)-(8) | CMS Requirements | Out-of-control periods, including reporting | Yes. |
§ 63.8(d) | CMS Quality Control | Requirements for CMS quality control, including calibration, etc. Must keep quality control plan on record for 5 years. Keep old versions for 5 years after revisions | Yes. |
§ 63.8(e) | CMS Performance Evaluation | Notification, performance evaluation test plan, reports | Yes. |
§ 63.8(f)(1)-(5) | Alternative Monitoring Method | Procedures for Administrator to approve alternative monitoring | Yes. |
§ 63.8(f)(6) | Alternative to Relative Accuracy Test | Procedures for Administrator to approve alternative relative accuracy tests for CEMS | No. |
§ 63.8(g)(1)-(4) | Data Reduction | COMS 6-minute averages calculated over at least 36 evenly spaced data points. CEMS 1-hour averages computed over at least four equally spaced data points | Yes. However, COMS are not applicable. Requirements for CPMS are addressed in §§ 63.7900 and 63.7913 . |
§ 63.8(g)(5) | Data Reduction | Data that cannot be used in computing averages for CEMS and COMS | No. |
§ 63.9(a) | Notification Requirements | Applicability and State Delegation | Yes. |
§ 63.9(b)(1)-(5) | Initial Notifications. | Submit notification 120 days after effective date. Notification of intent to construct/reconstruct; Notification of commencement of construct/reconstruct; Notification of startup. Contents of each | Yes. |
§ 63.9(c) | Request for Compliance Extension | Can request if cannot comply by date or if installed BACT/LAER | Yes. |
§ 63.9(d) | Notification of Special Compliance Requirements for New Source | For sources that commence construction between proposal and promulgation and want to comply 3 years after effective date | Yes. |
§ 63.9(e) | Notification of Performance Test | Notify Administrator 60 days prior | Yes. |
§ 63.9(f) | Notification of VE/Opacity Test | Notify Administrator 30 days prior | No. |
§ 63.9(g) | Additional Notifications When Using CMS | Notification of performance evaluation. Notification using COMS data. Notification that exceeded criterion for relative accuracy | Yes. However, there are no opacity standards. |
§ 63.9(h)(1)-(6) | Notification of Compliance Status | Contents. Due 60 days after end of performance test or other initial compliance demonstration, except for opacity/VE, which are due 30 days after. When to submit to Federal vs. State authority | Yes. |
§ 63.9(i) | Adjustment of Submittal Deadlines | Procedures for Administrator to approve change in when notifications must be submitted | Yes. |
§ 63.9(j) | Change in Previous Information | Must submit within 15 days after the change | Yes. |
§ 63.9(k) | Electronic reporting procedures | Electronic reporting procedures for notifications per § 63.9(j) | Yes. |
§ 63.10(a) | Recordkeeping/Reporting | Applies to all, unless compliance extension. When to submit to Federal vs. State authority. Procedures for owners of more than 1 source | Yes. |
§ 63.10(b)(1) | Recordkeeping/Reporting | General Requirements. Keep all records readily available. Keep for 5 years | Yes. |
§ 63.10(b)(2)(i) and (ii) | Records related to SSM | Exceedance of emission limit during startup, shutdown or malfunction | No, for new sources for which initial startup is after September 3, 2019. Yes, for all other affected sources before January 7, 2021, and No thereafter. |
§ 63.10(b)(2)(iii) | Maintenance Records | Maintenance on air pollution control equipment. | Yes. |
§ 63.10(b)(2)(iv) and (v) | Records related to SSM | Actions during SSM. | No, for new sources for which initial startup is after September 3, 2019. Yes, for all other affected sources before January 7, 2021, and No thereafter. |
§ 63.10(b)(2)(vi) and (x-xi) | CMS Records | Malfunctions, inoperative, out-of-control. Calibration checks. Adjustments, maintenance | Yes. |
§ 63.10(b)(2)(vii)-(ix) | Records | Measurements to demonstrate compliance with emissions limitations. Performance test, performance evaluation, and visible emissions observation results. Measurements to determine conditions of performance tests and performance evaluations | Yes. |
§ 63.10(b)(2)(xii) | Records | Records when under waiver | Yes. |
§ 63.10(b)(2) (xiii) | Records | Records when using alternative to relative accuracy test | No. |
§ 63.10(b)(2)(xiv) | Records | All documentation supporting Initial Notification and Notification of Compliance Status | Yes. |
§ 63.10(b)(3) | Records | Applicability Determinations | Yes. |
§ 63.10(c) | Records | Additional Records for CMS | No. |
§ 63.10(d)(1) | General Reporting Requirements | Requirement to report | Yes. |
§ 63.10(d)(2) | Report of Performance Test Results | When to submit to Federal or State authority | Yes. |
§ 63.10(d)(3) | Reporting Opacity or VE Observations | What to report and when | No. |
§ 63.10(d)(4) | Progress Reports | Must submit progress reports on schedule if under compliance extension | Yes. |
§ 63.10(d)(5) | Startup, Shutdown, and Malfunction Reports | Contents and submission | No, see § 63.7951(b)(4) . |
§ 63.10(e)(1)-(2) | Additional CMS Reports | Must report results for each CEM on a unit Written copy of performance evaluation Three copies of COMS performance evaluation | Yes. However, COMS are not applicable. |
§ 63.10(e)(3) | Reports | Excess Emissions Reports | No. |
§ 63.10(e)(3) (i-iii) | Reports | Schedule for reporting excess emissions and parameter monitor exceedance (now defined as deviations) | No. |
§ 63.10(e)(3) (iv-v) | Excess Emissions Reports | Requirement to revert to quarterly submission if there is an excess emissions and parameter monitor exceedance (now defined as deviations). Provision to request semiannual reporting after compliance for one year. Submit report by 30th day following end of quarter or calendar half. If there has not been an exceedance or excess emissions (now defined as deviations), report contents is a statement that there have been no deviations | No. |
§ 63.10(e)(3) (iv-v) | Excess Emissions Reports | Must submit report containing all of the information in §§ 63.10(c) (5-13) and 63.8(c)(7-8) | No. |
§ 63.10(e)(3) (vi-viii) | Excess Emissions Report and Summary Report | Requirements for reporting excess emissions for CMSs (now called deviations). Requires all of the information in §§ 63.10(c) (5-13) and 63.8(c)(7-8) | No. |
§ 63.10(e)(4) | Reporting COMS data | Must submit COMS data with performance test data | No. |
§ 63.10(f) | Waiver for Recordkeeping/Reporting | Procedures for Administrator to waive | Yes. |
§ 63.11 | Control and work practice requirements | Requirements for flares and alternative work practice for equipment leaks | Yes. |
§ 63.12 | Delegation | State authority to enforce standards | Yes. |
§ 63.13 | Addresses | Addresses where reports, notifications, and requests are sent | Yes, only applicable to those reports not required to be submitted electronically. |
§ 63.14 | Incorporation by Reference | Test methods incorporated by reference | Yes. |
§ 63.15 | Availability of Information | Public and confidential information | Yes. |
40 C.F.R. 63.1662-63 app Table 3 to Subpart GGGGG of Part 63