40 C.F.R. § 62 app Table 1 to Subpart III of Part 62

Current through November 30, 2024
Appendix Table 1 to Subpart III of Part 62 - Emission Limitations

For the air pollutantYou must meet this emission limitation aUsing this averaging timeAnd determining compliance using this method
Cadmium0.004 milligrams per dry standard cubic meter3-run average (1 hour minimum sample time per run)Performance test (Method 29 of appendix A of part 60).
Carbon monoxide157 parts per million by dry volume3-run average (1 hour minimum sample time per run)Performance test (Method 10, 10A, or 10B, of appendix A of part 60).
Dioxins/furans (toxic equivalency basis)0.41 nanograms per dry standard cubic meter3-run average (4 hour minimum sample time per run)Performance test (Method 23 of appendix A of part 60).
Hydrogen chloride62 parts per million by dry volume3-run average (1 hour minimum sample time per run)Performance test (Method 26A of appendix A of part 60).
Lead0.04 milligrams per dry standard cubic meter3-run (1 hour minimum sample time per run)Performance test (Method 29 of appendix A of part 60).
Mercury0.47 milligrams per dry standard cubic meter3-run average (1 hour minimum sample time per run)Performance test (Method 29 of appendix A of part 60).
Opacity10 percent6-minute averagesPerformance test (Method 9 of appendix A of part 60).
Oxides of nitrogen388 parts per million by dry volume3-run average (1 hour minimum sample time per run)Performance test (Methods 7, 7A, 7C, 7D, or 7E of appendix A of part 60).
Particulate matter70 milligrams per dry standard cubic meter3-run average (1 hour minimum sample time per run)Performance test (Method 5 or 29 of appendix A of part 60).
Sulfur dioxide20 parts per million by dry volume3-run average (1 hour minimum sample time per run)Performance test (Method 6 or 6c of appendix A of part 60).

a All emission limitations (except for opacity) are measured at 7 percent oxygen, dry basis at standard conditions.

40C.F.R. 62 app Table 1 to Subpart III of Part 62