Current through October 31, 2024
Section 60.3033 - How do I demonstrate continuous compliance with the emission limitations and the operating limits?(a) You must conduct an annual performance test for all of the pollutants in table 2 of this subpart for each OSWI unit to determine compliance with the emission limitations. The annual performance test must be conducted using the test methods listed in table 2 of this subpart and the procedures in § 60.3027 .(b) You must continuously monitor carbon monoxide emissions to determine compliance with the carbon monoxide emissions limitation. Twelve-hour rolling average values are used to determine compliance. A 12-hour rolling average value above the carbon monoxide emission limit in table 2 constitutes a deviation from the emission limitation.(c) You must continuously monitor the operating parameters specified in § 60.3023 or established under § 60.3024 . Three-hour rolling average values are used to determine compliance with the operating limits unless a different averaging period is established under § 60.3024 . A 3-hour rolling average value (unless a different averaging period is established under § 60.3024 ) above the established maximum or below the established minimum operating limits constitutes a deviation from the established operating limits. Operating limits do not apply during performance tests.