Current through October 31, 2024
Section 60.585 - Reporting requirements(a) For all affected facilities subject to compliance with § 60.582 , the performance test data and results from the performance test shall be submitted to the Administrator as specified in § 60.8(a) .(b) The owner or operator of each affected facility shall submit semiannual reports to the Administrator of occurrences of the following: (1) Exceedances of the weighted average VOC content specified in § 60.582(a)(1) ;(2) Exceedances of the average value of the exhaust vent VOC concentration as defined under § 60.584(a)(2) ;(3) Drops in the incinerator temperature as defined under § 60.584(b)(2) ; and(4) Drops in the average temperature of the gas stream immediately before the catalyst bed or drops in the average temperature across the catalyst bed as defined under § 60.584(c)(2) .(c) The reports required under paragraph (b) shall be postmarked within 30 days following the end of the second and fourth calendar quarters.(d) The requirements of this subsection remain in force until and unless the Agency, in delegating enforcement authority to a State under section 111(c) of the Act, approves reporting requirements or an alternative means of compliance surveillance adopted by such States. In that event, affected sources within the State will be relieved of the obligation to comply with this subsection, provided that they comply with requirements established by the State.