State | Annual EGU SO2 budget for 2010-2014 (tons) | Annual EGU SO2 budget for 2015 and thereafter (tons) |
Alabama | 157,582 | 110,307 |
Delaware | 22,411 | 15,687 |
District of Columbia | 708 | 495 |
Florida | 253,450 | 177,415 |
Georgia | 213,057 | 149,140 |
Illinois | 192,671 | 134,869 |
Indiana | 254,599 | 178,219 |
Iowa | 64,095 | 44,866 |
Kentucky | 188,773 | 132,141 |
Louisiana | 59,948 | 41,963 |
Maryland | 70,697 | 49,488 |
Michigan | 178,605 | 125,024 |
Minnesota | 49,987 | 34,991 |
Mississippi | 33,763 | 23,634 |
Missouri | 137,214 | 96,050 |
New Jersey | 32,392 | 22,674 |
New York | 135,139 | 94,597 |
North Carolina | 137,342 | 96,139 |
Ohio | 333,520 | 233,464 |
Pennsylvania | 275,990 | 193,193 |
South Carolina | 57,271 | 40,089 |
Tennessee | 137,216 | 96,051 |
Texas | 320,946 | 224,662 |
Virginia | 63,478 | 44,435 |
West Virginia | 215,881 | 151,117 |
Wisconsin | 87,264 | 61,085 |
(A) The total amount of Acid Rain allowances allocated under the Acid Rain Program to the sources in the State for that year; and
(B) If the State's SIP revision contains only control measures on EGUs, the State's Annual EGU SO2 Budget for the appropriate period as specified in paragraph (e)(2) of this section or, if the State's SIP revision contains control measures on EGUs and non-EGUs, the State's Annual EGU SO2 Budget for the appropriate period as specified in the SIP revision.
Acid Rain allowance means a limited authorization issued by the Administrator under the Acid Rain Program to emit up to one ton of sulfur dioxide during the specified year or any year thereafter, except as otherwise provided by the Administrator.
Acid Rain Program means a multi-State sulfur dioxide and nitrogen oxides air pollution control and emissions reduction program established by the Administrator under title IV of the CAA and parts 72 through 78 of this chapter.
Administrator means the Administrator of the United States Environmental Protection Agency or the Administrator's duly authorized representative.
Allocate or allocation means, with regard to allowances, the determination of the amount of allowances to be initially credited to a source or other entity.
Biomass means-
Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to recirculating water, steam, or other medium.
Bottoming-cycle cogeneration unit means a cogeneration unit in which the energy input to the unit is first used to produce useful thermal energy and at least some of the reject heat from the useful thermal energy application or process is then used for electricity production.
Clean Air Act or CAA means the Clean Air Act, 42 U.S.C. 7401 , et seq.
Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine:
Combustion turbine means:
Commence operation means to have begun any mechanical, chemical, or electronic process, including, with regard to a unit, start-up of a unit's combustion chamber.
Electric generating unit or EGU means:
Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material.
Fossil-fuel-fired means, with regard to a unit, combusting any amount of fossil fuel in any calendar year.
Generator means a device that produces electricity.
Maximum design heat input means the maximum amount of fuel per hour (in Btu/hr) that a unit is capable of combusting on a steady state basis as of the initial installation of the unit as specified by the manufacturer of the unit.
NAAQS means National Ambient Air Quality Standard.
Nameplate capacity means, starting from the initial installation of a generator, the maximum electrical generating output (in MWe) that the generator is capable of producing on a steady state basis and during continuous operation (when not restricted by seasonal or other deratings as of such installation as specified by the manufacturer of the generator or, starting from the completion of any subsequent physical change in the generator resulting in an increase in the maximum electrical generating output (in MWe) that the generator is capable of producing on a steady state basis and during continuous operation (when not restricted by seasonal or other deratings), such increased maximum amount as of such completion as specified by the person conducting the physical change.
Non-EGU means a source of SO2 emissions that is not an EGU.
Potential electrical output capacity means 33 percent of a unit's maximum design heat input, divided by 3,413 Btu/kWh, divided by 1,000 kWh/MWh, and multiplied by 8,760 hr/yr.
Sequential use of energy means:
Solid waste incineration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a "solid waste incineration unit" as defined in section 129(g)(1) of the Clean Air Act.
Topping-cycle cogeneration unit means a cogeneration unit in which the energy input to the unit is first used to produce useful power, including electricity, and at least some of the reject heat from the electricity production is then used to provide useful thermal energy.
Total energy input means, with regard to a cogeneration unit, total energy of all forms supplied to the cogeneration unit, excluding energy produced by the cogeneration unit itself.
Total energy output means, with regard to a cogeneration unit, the sum of useful power and useful thermal energy produced by the cogeneration unit. Each form of energy supplied shall be measured by the lower heating value of that form of energy calculated as follows:
LHV = HHV - 10.55(W + 9H)
Where:
LHV = lower heating value of fuel in Btu/lb,
HHV = higher heating value of fuel in Btu/lb,
W = Weight % of moisture in fuel, and
H = Weight % of hydrogen in fuel.
Unit means a stationary, fossil-fuel-fired boiler or a stationary, fossil-fuel fired combustion turbine.
Useful power means, with regard to a cogeneration unit, electricity or mechanical energy made available for use, excluding any such energy used in the power production process (which process includes, but is not limited to, any on-site processing or treatment of fuel combusted at the unit and any on-site emission controls).
Useful thermal energy means, with regard to a cogeneration unit, thermal energy that is:
Utility power distribution system means the portion of an electricity grid owned or operated by a utility and dedicated to delivering electricity to customers.
40 C.F.R. §51.124