Table 1-Shift Adjustment Multiplier by Hours of Operation and Building Type
Building activity/type | Weekly hours of operation | ||
50 or less | 51 to 167 | 168 | |
Admin/professional office | 1 | 1 | 1.4 |
Bank/other financial | 1 | 1 | 1.4 |
Government office | 1 | 1 | 1.4 |
Medical office(non-diagnostic) | 1 | 1 | 1.4 |
Mixed-use office | 1 | 1 | 1.4 |
Other office | 1 | 1 | 1.4 |
Laboratory | 1 | 1 | 1.4 |
Distribution/shipping center | 0.7 | 1.4 | 2.1 |
Nonrefrigerated warehouse | 0.7 | 1.4 | 2.1 |
Convenience store | 1 | 1 | 1.4 |
Convenience store with gas | 1 | 1 | 1.4 |
Grocery store/food market | 1 | 1 | 1.4 |
Other food sales | 1 | 1 | 1.4 |
Fire station/police station | 0.8 | 0.8 | 1.1 |
Other public order and safety | 0.8 | 0.8 | 1.1 |
Medical office (diagnostic) | 1 | 1 | 1.5 |
Clinic/other outpatient health | 1 | 1 | 1.5 |
Refrigerated warehouse | 1 | 1 | 1 |
Religious worship | 0.9 | 1.7 | 1.7 |
Entertainment/culture | 0.8 | 1.5 | 1.5 |
Library | 0.8 | 1.5 | 1.5 |
Recreation | 0.8 | 1.5 | 1.5 |
Social/meeting | 0.8 | 1.5 | 1.5 |
Other public assembly | 0.8 | 1.5 | 1.5 |
College/university | 0.8 | 1.3 | 1.3 |
Elementary/middle school | 0.8 | 1.3 | 1.3 |
High school | 0.8 | 1.3 | 1.3 |
Preschool/daycare | 0.8 | 1.3 | 1.3 |
Other classroom education | 0.8 | 1.3 | 1.3 |
Fast food | 0.4 | 1.1 | 2.1 |
Restaurant/cafeteria | 0.4 | 1.1 | 2.1 |
Other food service | 0.4 | 1.1 | 2.1 |
Hospital/inpatient health | 1 | 1 | 1 |
Nursing home/assisted living | 1 | 1 | 1 |
Dormitory/fraternity/sorority | 1 | 1 | 1 |
Hotel | 1 | 1 | 1 |
Motel or inn | 1 | 1 | 1 |
Other lodging | 1 | 1 | 1 |
Vehicle dealership/showroom | 0.8 | 1.2 | 1.8 |
Retail store | 0.8 | 1.2 | 1.8 |
Other retail | 0.8 | 1.2 | 1.8 |
Post office/postal center | 0.7 | 1.5 | 1.5 |
Repair shop | 0.7 | 1.5 | 1.5 |
Vehicle service/repair shop | 0.7 | 1.5 | 1.5 |
Vehicle storage/maintenance | 0.7 | 1.5 | 1.5 |
Other service | 0.7 | 1.5 | 1.5 |
Strip shopping mall | 1 | 1 | 1 |
Enclosed mall | 1 | 1 | 1 |
Bar/Pub/Lounge | 1 | 1 | 1.4 |
Courthouse/Probation Office | 1 | 1 | 1.4 |
Equation 1: Scope 1 Fossil fuel generated energy consumption for a mixed-use building = the sum across all building uses of (the fraction of total floor building floor area for building use i times the allowable fossil fuel-generated energy consumption for building use i)
Equation 1 may be rewritten as:
10 C.F.R. §435.200