The energy and water (in the case of faucets, showerheads, water closets, and urinals) conservation standards for the covered product classes are:
Table 1 to Paragraph (a)(1)
Product class | Equations for maximum energy use (kWh/yr) | |
based on AV (ft3) | based on av (L) | |
1. Refrigerators and refrigerator-freezers with manual defrost | 7.99AV + 225.0 | 0.282av + 225.0. |
1A. All-refrigerators-manual defrost | 6.79AV + 193.6 | 0.240av + 193.6. |
2. Refrigerator-freezers-partial automatic defrost | 7.99AV + 225.0 | 0.282av + 225.0. |
3. Refrigerator-freezers-automatic defrost with top-mounted freezer without an automatic icemaker | 8.07AV + 233.7 | 0.285av + 233.7. |
3-BI. Built-in refrigerator-freezer-automatic defrost with top-mounted freezer without an automatic icemaker | 9.15AV + 264.9 | 0.323av + 264.9. |
3I. Refrigerator-freezers-automatic defrost with top-mounted freezer with an automatic icemaker without through-the-door ice service | 8.07AV + 317.7 | 0.285av + 317.7. |
3I-BI. Built-in refrigerator-freezers-automatic defrost with top-mounted freezer with an automatic icemaker without through-the-door ice service | 9.15AV + 348.9 | 0.323av + 348.9. |
3A. All-refrigerators-automatic defrost | 7.07AV + 201.6 | 0.250av + 201.6. |
3A-BI. Built-in All-refrigerators-automatic defrost | 8.02AV + 228.5 | 0.283av + 228.5. |
4. Refrigerator-freezers-automatic defrost with side-mounted freezer without an automatic icemaker | 8.51AV + 297.8 | 0.301av + 297.8. |
4-BI. Built-In Refrigerator-freezers-automatic defrost with side-mounted freezer without an automatic icemaker | 10.22AV + 357.4 | 0.361av + 357.4. |
4I. Refrigerator-freezers-automatic defrost with side-mounted freezer with an automatic icemaker without through-the-door ice service | 8.51AV + 381.8 | 0.301av + 381.8. |
4I-BI. Built-In Refrigerator-freezers-automatic defrost with side-mounted freezer with an automatic icemaker without through-the-door ice service | 10.22AV + 441.4.2 | 0.361av + 441.4. |
5. Refrigerator-freezers-automatic defrost with bottom-mounted freezer without an automatic icemaker | 8.85AV + 317.0 | 0.312av + 317.0. |
5-BI. Built-In Refrigerator-freezers-automatic defrost with bottom-mounted freezer without an automatic icemaker | 9.40AV + 336.9 | 0.332av + 336.9. |
5I. Refrigerator-freezers-automatic defrost with bottom-mounted freezer with an automatic icemaker without through-the-door ice service | 8.85AV + 401.0 | 0.312av + 401.0. |
5I-BI. Built-In Refrigerator-freezers-automatic defrost with bottom-mounted freezer with an automatic icemaker without through-the-door ice service | 9.40AV + 420.9 | 0.332av + 420.9. |
5A. Refrigerator-freezer-automatic defrost with bottom-mounted freezer with through-the-door ice service | 9.25AV + 475.4 | 0.327av + 475.4. |
5A-BI. Built-in refrigerator-freezer-automatic defrost with bottom-mounted freezer with through-the-door ice service | 9.83AV + 499.9 | 0.347av + 499.9. |
6. Refrigerator-freezers-automatic defrost with top-mounted freezer with through-the-door ice service | 8.40AV + 385.4 | 0.297av + 385.4. |
7. Refrigerator-freezers-automatic defrost with side-mounted freezer with through-the-door ice service | 8.54AV + 432.8 | 0.302av + 431.1. |
7-BI. Built-In Refrigerator-freezers-automatic defrost with side-mounted freezer with through-the-door ice service | 10.25AV + 502.6 | 0.362av + 502.6. |
8. Upright freezers with manual defrost | 5.57AV + 193.7 | 0.197av + 193.7. |
9. Upright freezers with automatic defrost without an automatic icemaker | 8.62AV + 228.3 | 0.305av + 228.3. |
9I. Upright freezers with automatic defrost with an automatic icemaker | 8.62AV + 312.3 | 0.305av + 312.3. |
9-BI. Built-In Upright freezers with automatic defrost without an automatic icemaker | 9.86AV + 260.9 | 0.348av + 260.6. |
9I-BI. Built-In Upright freezers with automatic defrost with an automatic icemaker | 9.86AV + 344.9 | 0.348av + 344.9. |
10. Chest freezers and all other freezers except compact freezers | 7.29AV + 107.8 | 0.257av + 107.8. |
10A. Chest freezers with automatic defrost | 10.24AV + 148.1 | 0.362av + 148.1. |
11. Compact refrigerators and refrigerator-freezers with manual defrost | 9.03AV + 252.3 | 0.319av + 252.3. |
11A.Compact refrigerators and refrigerator-freezers with manual defrost | 7.84AV + 219.1 | 0.277av + 219.1. |
12. Compact refrigerator-freezers-partial automatic defrost | 5.91AV + 335.8 | 0.209av + 335.8. |
13. Compact refrigerator-freezers-automatic defrost with top-mounted freezer | 11.80AV + 339.2 | 0.417av + 339.2. |
13I. Compact refrigerator-freezers-automatic defrost with top-mounted freezer with an automatic icemaker | 11.80AV + 423.2 | 0.417av + 423.2. |
13A. Compact all-refrigerator-automatic defrost | 9.17AV + 259.3 | 0.324av + 259.3. |
14. Compact refrigerator-freezers-automatic defrost with side-mounted freezer | 6.82AV + 456.9 | 0.241av + 456.9. |
14I. Compact refrigerator-freezers-automatic defrost with side-mounted freezer with an automatic icemaker | 6.82AV + 540.9 | 0.241av + 540.9. |
15. Compact refrigerator-freezers-automatic defrost with bottom-mounted freezer | 11.80AV + 339.2 | 0.417av + 339.2. |
15I. Compact refrigerator-freezers-automatic defrost with bottom-mounted freezer with an automatic icemaker | 11.80AV + 423.2 | 0.417av + 423.2. |
16. Compact upright freezers with manual defrost | 8.65AV + 225.7 | 0.306av + 225.7. |
17. Compact upright freezers with automatic defrost | 10.17AV + 351.9 | 0.359av + 351.9. |
18. Compact chest freezers | 9.25AV + 136.8 | 0.327av + 136.8. |
AV = Total adjusted volume, expressed in ft3, as determined in appendices A and B to subpart B of this part.
av = Total adjusted volume, expressed in Liters.
Table 2 to Paragraph (a)(2)
Product class | Equations for maximum energy use (kWh/yr) | |
Based on AV (ft3) | Based on av (L) | |
3-BI. Built-in refrigerator-freezer-automatic defrost with top-mounted freezer | 8.24AV + 238.4 + 28I | 0.291av + 238.4 + 28I. |
3A-BI. Built-in All-refrigerators-automatic defrost | (7.22AV + 205.7) * K3ABI | (0.255av + 205.7) * K3ABI. |
4-BI. Built-In Refrigerator-freezers-automatic defrost with side-mounted freezer | (8.79AV + 307.4) * K4BI + 28I | (0.310av + 307.4) * K4BI + 28I. |
5-BI. Built-In Refrigerator-freezers-automatic defrost with bottom-mounted freezer | (8.65AV + 309.9) * K5BI + 28I | (0.305av + 309.9) * K5BI + 28I. |
5A. Refrigerator-freezer-automatic defrost with bottom-mounted freezer with through-the-door ice service | (7.76AV + 351.9) * K5A | (0.274av + 351.9) * K5A. |
5A-BI. Built-in refrigerator-freezer-automatic defrost with bottom-mounted freezer with through-the-door ice service | (8.21AV + 370.7) * K5ABI | (0.290av + 370.7) * K5ABI. |
7-BI. Built-In Refrigerator-freezers-automatic defrost with side-mounted freezer with through-the-door ice service | (8.82AV + 384.1) * K7BI | (0.311av + 384.1) * K7BI. |
8. Upright freezers with manual defrost | 5.57AV + 193.7 | 0.197av + 193.7. |
9-BI. Built-In Upright freezers with automatic defrost | (9.37AV + 247.9) * K9BI + 28I | (0.331av + 247.9) * K9BI + 28I. |
9A-BI. Built-In Upright freezers with automatic defrost with through-the-door ice service | 9.86AV + 288.9 | 0.348av + 288.9. |
10. Chest freezers and all other freezers except compact freezers | 7.29AV + 107.8 | 0.257av + 107.8. |
10A. Chest freezers with automatic defrost | 10.24AV + 148.1 | 0.362av + 148.1. |
11. Compact refrigerator-freezers and refrigerators other than all-refrigerators with manual defrost | 7.68AV + 214.5 | 0.271av + 214.5. |
11A. Compact all-refrigerators-manual defrost | 6.66AV + 186.2 | 0.235av + 186.2. |
12. Compact refrigerator-freezers-partial automatic defrost | (5.32AV + 302.2) * K12 | (0.188av + 302.2) * K12. |
13. Compact refrigerator-freezers-automatic defrost with top-mounted freezer | 10.62AV + 305.3 + 28I | 0.375av + 305.3 + 28I. |
13A. Compact all-refrigerators-automatic defrost | (8.25AV + 233.4) * K13A | (0.291av + 233.4) * K13A. |
14. Compact refrigerator-freezers-automatic defrost with side-mounted freezer | 6.14AV + 411.2 + 28I | 0.217av + 411.2 + 28I. |
15. Compact refrigerator-freezers-automatic defrost with bottom-mounted freezer | 10.62AV + 305.3 + 28I | 0.375av + 305.3 + 28I. |
16. Compact upright freezers with manual defrost | 7.35AV + 191.8 | 0.260av + 191.8. |
17. Compact upright freezers with automatic defrost | 9.15AV + 316.7 | 0.323av + 316.7. |
18. Compact chest freezers | 7.86AV + 107.8 | 0.278av + 107.8. |
AV = Total adjusted volume, expressed in ft3, as determined in appendices A and B to subpart B of this part.
av = Total adjusted volume, expressed in Liters.
I = 1 for a product with an automatic icemaker and = 0 for a product without an automatic icemaker. Door Coefficients (e.g., K3ABI) are as defined in the following table.
Table 3 to Paragraph (a)(2)
Door coefficient | Products with a transparent door | Products without a transparent door with a door-in-door | Products without a transparent door or door-in-door with added external doors |
K3ABI | 1.10 | 1.0 | 1.0. |
K4BI | 1.10 | 1.06 | 1 + 0.02 * (Nd-2). |
K5BI | 1.10 | 1.06 | 1 + 0.02 * (Nd-2). |
K5A | 1.10 | 1.06 | 1 + 0.02 * (Nd-3). |
K5ABI | 1.10 | 1.06 | 1 + 0.02 * (Nd-3). |
K7BI | 1.10 | 1.06 | 1 + 0.02 * (Nd-2). |
K9BI | 1.0 | 1.0 | 1 + 0.02 * (Nd-1). |
K12 | 1.0 | 1.0 | 1 + 0.02 * (Nd-1). |
K13A | 1.10 | 1.0 | 1.0. |
Notes:
1 Nd is the number of external doors.
2 The maximum Nd values are 2 for K12, 3 for K9BI, and 5 for all other K values.
Table 4 to Paragraph (a)(3)
Product class | Equations for maximum energy use (kWh/yr) | |
Based on AV (ft3) | Based on av (L) | |
1. Refrigerator-freezers and refrigerators other than all-refrigerators with manual defrost | 6.79AV + 191.3 | 0.240av + 191.3. |
1A. All-refrigerators-manual defrost | 5.77AV + 164.6 | 0.204av + 164.6. |
2. Refrigerator-freezers-partial automatic defrost | (6.79AV + 191.3) * K2 | (0.240av + 191.3) * K2. |
3. Refrigerator-freezers-automatic defrost with top-mounted freezer | 6.86AV + 198.6 + 28I | 0.242av + 198.6 + 28I. |
3A. All-refrigerators-automatic defrost | (6.01AV + 171.4) * K3A | (0.212av + 171.4) * K3A. |
4. Refrigerator-freezers-automatic defrost with side-mounted freezer | (7.28AV + 254.9) * K4 + 28I | (0.257av + 254.9) * K4 + 28I. |
5. Refrigerator-freezers-automatic defrost with bottom-mounted freezer | (7.61AV + 272.6) * K5 + 28I | (0.269av + 272.6) * K5 + 28I. |
6. Refrigerator-freezers-automatic defrost with top-mounted freezer with through-the-door ice service | 7.14AV + 280.0 | 0.252av + 280.0. |
7. Refrigerator-freezers-automatic defrost with side-mounted freezer with through-the-door ice service | (7.31AV + 322.5) * K7 | (0.258av + 322.5) * K7. |
9. Upright freezers with automatic defrost | (7.33AV + 194.1) * K9 + 28I | (0.259av + 194.1) * K9 + 28I. |
AV = Total adjusted volume, expressed in ft3, as determined in appendices A and B to subpart B of this part.
av = Total adjusted volume, expressed in Liters.
I = 1 for a product with an automatic icemaker and = 0 for a product without an automatic icemaker. Door Coefficients (e.g., K3A) are as defined in the following table.
Table 5 to Paragraph (a)(3)
Door coefficient | Products with a transparent door | Products without a transparent door with a door-in-door | Products without a transparent door or door-in-door with added external doors |
K2 | 1.0 | 1.0 | 1 + 0.02 * (Nd-1). |
K3A | 1.10 | 1.0 | 1.0. |
K4 | 1.10 | 1.06 | 1 + 0.02 * (Nd-2). |
K5 | 1.10 | 1.06 | 1 + 0.02 * (Nd-2). |
K7 | 1.10 | 1.06 | 1 + 0.02 * (Nd-2). |
K9 | 1.0 | 1.0 | 1 + 0.02 * (Nd-1). |
Notes:
1 Nd is the number of external doors.
2 The maximum Nd values are 2 for K2, and 5 for all other K values.
table 6 to paragraph (b)(1)
Equipment class | Combined energy efficiency ratio |
1. Without reverse cycle, with louvered sides, and with a certified cooling capacity 1 less than 6,000 Btu/h | 11.0 |
2. Without reverse cycle, with louvered sides and with a certified cooling capacity of 6,000 to 7,999 Btu/h | 11.0 |
3. Without reverse cycle, with louvered sides and with a certified cooling capacity of 8,000 to 13,999 Btu/h | 10.9 |
4. Without reverse cycle, with louvered sides and with a certified cooling capacity of 14,000 to 19,999 Btu/h | 10.7 |
5a. Without reverse cycle, with louvered sides and with a certified cooling capacity of 20,000 Btu/h to 27,999 Btu/h | 9.4 |
5b. Without reverse cycle, with louvered sides and with a certified cooling capacity of 28,000 Btu/h or more | 9.0 |
6. Without reverse cycle, without louvered sides, and with a certified cooling capacity less than 6,000 Btu/h | 10.0 |
7. Without reverse cycle, without louvered sides and with a certified cooling capacity of 6,000 to 7,999 Btu/h | 10.0 |
8a. Without reverse cycle, without louvered sides and with a certified cooling capacity of 8,000 to 10,999 Btu/h | 9.6 |
8b. Without reverse cycle, without louvered sides and with a certified cooling capacity of 11,000 to 13,999 Btu/h | 9.5 |
9. Without reverse cycle, without louvered sides and with a certified cooling capacity of 14,000 to 19,999 Btu/h | 9.3 |
10. Without reverse cycle, without louvered sides and with a certified cooling capacity of 20,000 Btu/h or more | 9.4 |
11. With reverse cycle, with louvered sides, and with a certified cooling capacity less than 20,000 Btu/h | 9.8 |
12. With reverse cycle, without louvered sides, and with a certified cooling capacity less than 14,000 Btu/h | 9.3 |
13. With reverse cycle, with louvered sides, and with a certified cooling capacity of 20,000 Btu/h or more | 9.3 |
14. With reverse cycle, without louvered sides, and with a certified cooling capacity of 14,000 Btu/h or more | 8.7 |
15. Casement-Only | 9.5 |
16. Casement-Slider | 10.4 |
1 The certified cooling capacity is determined by the manufacturer in accordance with 10 CFR 429.15(a)(3) .
table 7 to paragraph (b)(2)
Equipment class | Combined energy efficiency ratio |
1. Without reverse cycle, with louvered sides, and with a certified cooling capacity 1 less than 6,000 Btu/h | 13.1 |
2. Without reverse cycle, with louvered sides and with a certified cooling capacity of 6,000 to 7,900 Btu/h | 13.7 |
3. Without reverse cycle, with louvered sides and with a certified cooling capacity of 8,000 to 13,900 Btu/h | 16.0 |
4. Without reverse cycle, with louvered sides and with a certified cooling capacity of 14,000 to 19,900 Btu/h | 16.0 |
5a. Without reverse cycle, with louvered sides and with a certified cooling capacity of 20,000 Btu/h to 27,900 Btu/h | 13.8 |
5b. Without reverse cycle, with louvered sides and with a certified cooling capacity of 28,000 Btu/h or more | 13.2 |
6. Without reverse cycle, without louvered sides, and with a certified cooling capacity less than 6,000 Btu/h | 12.8 |
7. Without reverse cycle, without louvered sides and with a certified cooling capacity of 6,000 to 7,900 Btu/h | 12.8 |
8a. Without reverse cycle, without louvered sides and with a certified cooling capacity of 8,000 to 10,900 Btu/h | 14.1 |
8b. Without reverse cycle, without louvered sides and with a certified cooling capacity of 11,000 to 13,900 Btu/h | 13.9 |
9. Without reverse cycle, without louvered sides and with a certified cooling capacity of 14,000 to 19,900 Btu/h | 13.7 |
10. Without reverse cycle, without louvered sides and with a certified cooling capacity of 20,000 Btu/h or more | 13.8 |
11. With reverse cycle, with louvered sides, and with a certified cooling capacity less than 20,000 Btu/h | 14.4 |
12. With reverse cycle, without louvered sides, and with a certified cooling capacity less than 14,000 Btu/h | 13.7 |
13. With reverse cycle, with louvered sides, and with a certified cooling capacity of 20,000 Btu/h or more | 13.7 |
14. With reverse cycle, without louvered sides, and with a certified cooling capacity of 14,000 Btu/h or more | 12.8 |
15. Casement-Only | 13.9 |
16. Casement-Slider | 15.3 |
1 The certified cooling capacity is determined by the manufacturer in accordance with 10 CFR 429.15(a)(3) .
Product class | Seasonal energy efficiency ratio (SEER) | Heating seasonal performance factor (HSPF) |
(i) Split systems - air conditioners | 13 | |
(ii) Split systems - heat pumps | 14 | 8.2 |
(iii) Single package units - air conditioners | 14 | |
(iv) Single package units - heat pumps | 14 | 8.0 |
(v) Small-duct, high-velocity systems | 12 | 7.2 |
(vi)(A) Space-constrained products - air conditioners | 12 | |
(vi)(B) Space-constrained products - heat pumps | 12 | 7.4 |
Product class | Energy efficiency ratio (EER) |
(i) Split systems - air conditioners with rated cooling capacity less than 45,000 Btu/hr | 12.2 |
(ii) Split systems - air conditioners with rated cooling capacity equal to or greater than 45,000 Btu/hr | 11.7 |
(iii) Single-package units - air conditioners | 11.0 |
Product class | Average off mode power consumption PW,OFF (watts) |
(i) Split-system air conditioners | 30 |
(ii) Split-system heat pumps | 33 |
(iii) Single-package air conditioners | 30 |
(iv) Single-package heat pumps | 33 |
(v) Small-duct, high-velocity systems | 30 |
(vi) Space-constrained air conditioners | 30 |
(vii) Space-constrained heat pumps | 33 |
Product class | Seasonal energy efficiency ratio 2 (SEER2) | Heating seasonal performance factor 2 (HSPF2) |
(i)(A) Split systems - air conditioners with a certified cooling capacity less than 45,000 Btu/hr | 13.4 | |
(i)(B) Split systems - air conditioners with a certified cooling capacity equal to or greater than 45,000 Btu/hr | 13.4 | |
(ii) Split systems - heat pumps | 14.3 | 7.5 |
(iii) Single-package units - air conditioners | 13.4 | |
(iv) Single-package units - heat pumps | 13.4 | 6.7 |
(v) Small-duct, high-velocity systems | 12 | 6.1 |
(vi)(A) Space-constrained products - air conditioners | 11.7 | |
(vi)(B) Space-constrained products - heat pumps | 11.9 | 6.3 |
Product class | Southeast * | Southwest ** | |
SEER2 | SEER2 | EER2 *** | |
(i)(A) Split-systems - air conditioners with a certified cooling capacity less than 45,000 Btu/hr | 14.3 | 14.3 | 11.7/9.8 [DAGGER] |
(i)(B) Split-systems - air conditioners with a certified cooling capacity equal to or greater than 45,000 Btu/hr | 13.8 | 13.8 | 11.2/9.8 [DAGGER][DAGGER] |
(iii) Single-package units - air conditioners | 10.6 |
* "Southeast" includes the States of Alabama, Arkansas, Delaware, Florida, Georgia, Hawaii, Kentucky, Louisiana, Maryland, Mississippi, North Carolina, Oklahoma, Puerto Rico, South Carolina, Tennessee, Texas, Virginia, the District of Columbia, and the U.S. Territories.
** "Southwest" includes the States of Arizona, California, Nevada, and New Mexico.
*** EER refers to the energy efficiency ratio at a standard rating of 95 °F dry bulb outdoor temperature.
[DAGGER] The 11.7 EER2 standard applies to products with a certified SEER2 less than 15.2. The 9.8 EER2 standard applies to products with a certified SEER2 greater than or equal to 15.2.
[DAGGER][DAGGER] The 11.2 EER2 standard applies to products with a certified SEER2 less than 15.2. The 9.8 EER2 standard applies to products with a certified SEER2 greater than or equal to 15.2.
Product class | Rated storage volume and input rating (if applicable) | Draw pattern | Uniform energy factor |
Gas-fired Storage Water Heater | [GREATER THAN EQUAL TO]20 gal and [LESS THAN EQUAL TO]55 gal | Very Small | 0.3456 - (0.0020 * Vr) |
Low | 0.5982 - (0.0019 * Vr) | ||
Medium | 0.6483 - (0.0017 * Vr) | ||
High | 0.6920 - (0.0013 * Vr) | ||
[GREATER THAN]55 gal and [LESS THAN EQUAL TO]100 gal | Very Small | 0.6470 - (0.0006 * Vr) | |
Low | 0.7689 - (0.0005 * Vr) | ||
Medium | 0.7897 - (0.0004 * Vr) | ||
High | 0.8072 - (0.0003 * Vr) | ||
Oil-fired Storage Water Heater | [LESS THAN EQUAL TO]50 gal | Very Small | 0.2509 - (0.0012 * Vr) |
Low | 0.5330 - (0.0016 * Vr) | ||
Medium | 0.6078 - (0.0016 * Vr) | ||
High | 0.6815 - (0.0014 * Vr) | ||
Electric Storage Water Heaters | [GREATER THAN EQUAL TO]20 gal and [LESS THAN EQUAL TO]55 gal | Very Small | 0.8808 - (0.0008 * Vr) |
Low | 0.9254 - (0.0003 * Vr) | ||
Medium | 0.9307 - (0.0002 * Vr) | ||
High | 0.9349 - (0.0001 * Vr) | ||
[GREATER THAN]55 gal and [LESS THAN EQUAL TO]120 gal | Very Small | 1.9236 - (0.0011 * Vr) | |
Low | 2.0440 - (0.0011 * Vr) | ||
Medium | 2.1171 - (0.0011 * Vr) | ||
High | 2.2418 - (0.0011 * Vr) | ||
Tabletop Water Heater | [GREATER THAN EQUAL TO]20 gal and [LESS THAN EQUAL TO]120 gal | Very Small | 0.6323 - (0.0058 * Vr) |
Low | 0.9188 - (0.0031 * Vr) | ||
Medium | 0.9577 - (0.0023 * Vr) | ||
High | 0.9884 - (0.0016 * Vr) | ||
Instantaneous Gas-fired Water Heater | [LESS THAN]2 gal and [GREATER THAN]50,000 Btu/h | Very Small Low | 0.80 0.81 |
Medium | 0.81 | ||
High | 0.81 | ||
Instantaneous Electric Water Heater | [LESS THAN]2 gal | Very Small | 0.91 |
Low | 0.91 | ||
Medium | 0.91 | ||
High | 0.92 | ||
Grid-Enabled Water Heater | [GREATER THAN]75 gal | Very Small | 1.0136 - (0.0028 * Vr) |
Low | 0.9984 - (0.0014 * Vr) | ||
Medium | 0.9853 - (0.0010 * Vr) | ||
High | 0.9720 - (0.0007 * Vr) |
* Vr is the Rated Storage Volume (in gallons), as determined pursuant to 10 CFR 429.17 .
Product class | AFUE (percent)1 |
(A) Furnaces (excluding classes noted below) | 78 |
(B) Mobile Home furnaces | 75 |
(C) Small furnaces (other than those designed solely for installation in mobile homes) having an input rate of less than 45,000 Btu/hr | |
(1) Weatherized (outdoor) | 78 |
(2) Non-weatherized (indoor) | 78 |
1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2) of this part.
Product class | AFUE (percent) 1 |
(A) Non-weatherized gas furnaces (not including mobile home furnaces) | 80.0 |
(B) Mobile home gas furnaces | 80.0 |
(C) Non-weatherized oil-fired furnaces (not including mobile home furnaces) | 83.0 |
(D) Mobile home oil-fired furnaces | 75.0 |
(E) Weatherized gas furnaces | 81.0 |
(F) Weatherized oil-fired furnaces | 78.0 |
(G) Electric furnaces | 78.0 |
1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2) .
Product class | AFUE (percent) 1 |
(A) Non-weatherized gas furnaces (not including mobile home gas furnaces) | 95.0 |
(B) Mobile home gas furnaces | 95.0 |
1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2) .
Product class | Maximum standby mode electrical power consumption, PW,SB (watts) | Maximum off mode electrical power consumption, PW,OFF (watts) |
(A) Non-weatherized oil-fired furnaces (including mobile home furnaces) | 11 | 11 |
(B) Electric furnaces | 10 | 10 |
Product class | AFUE1 (percent) |
(A) Boilers (excluding gas steam) | 80 |
(B) Gas steam boilers | 75 |
1 Annual Fuel Utilization Efficiency, as determined in § 430.22(n)(2) of this part.
Product class | AFUE1 (percent) | Design requirements |
(A) Gas-fired hot water boiler | 82 | Constant burning pilot not permitted. Automatic means for adjusting water temperature required (except for boilers equipped with tankless domestic water heating coils). |
(B) Gas-fired steam boiler | 80 | Constant burning pilot not permitted. |
(C) Oil-fired hot water boiler | 84 | Automatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils). |
(D) Oil-fired steam boiler | 82 | None. |
(E) Electric hot water boiler | None | Automatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils). |
1 Annual Fuel Utilization Efficiency, as determined in § 430.22(n)(2) of this part.
Product class | AFUE1 (percent) | Design requirements |
(1) Gas-fired hot water boiler | 84 | Constant-burning pilot not permitted. Automatic means for adjusting water temperature required (except for boilers equipped with tankless domestic water heating coils). |
(2) Gas-fired steam boiler | 82 | Constant-burning pilot not permitted. |
(3) Oil-fired hot water boiler | 86 | Automatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils). |
(4) Oil-fired steam boiler | 85 | None. |
(5) Electric hot water boiler | None | Automatic means for adjusting temperature required (except for boilers equipped with tankless domestic water heating coils). |
(6) Electric steam boiler | None | None. |
1 Annual Fuel Utilization Efficiency, as determined in § 430.23(n)(2) of this part.
Product class | PW,SB (watts) | PW,OFF (watts) |
(1) Gas-fired hot water boiler | 9 | 9 |
(2) Gas-fired steam boiler | 8 | 8 |
(3) Oil-fired hot water boiler | 11 | 11 |
(4) Oil-fired steam boiler | 11 | 11 |
(5) Electric hot water boiler | 8 | 8 |
(6) Electric steam boiler | 8 | 8 |
Product class | Estimated annual energy use (kWh/year) | Maximum per-cycle water consumption (gal/cycle) |
(i) Standard-size 1 ([GREATER THAN EQUAL TO]8 place settings plus 6 serving pieces) 2 | 223 | 3.3 |
(ii) Compact-size (<8 place settings plus 6 serving pieces) 2 | 174 | 3.1 |
1 The energy conservation standards in this table do not apply to standard-size dishwashers with a cycle time for the normal cycle of 60 minutes or less.
2 Place settings are as specified in AHAM DW-1-2020 (incorporated by reference, see § 430.3 ) and the test load is as specified in section 2.4 of appendix C2 to subpart B of this part.
Product class | Integrated modified energy factor (cu.ft./kWh/cycle) | Integrated water factor (gal/cycle/cu.ft.) |
(i) Top-loading, Compact (less than 1.6 ft3 capacity) | 1.15 | 12.0 |
(ii) Top-loading, Standard (1.6 ft3 or greater capacity) | 1.57 | 6.5 |
(iii) Front-loading, Compact (less than 1.6 ft3 capacity) | 1.13 | 8.3 |
(iv) Front-loading, Standard (1.6 ft3 or greater capacity) | 1.84 | 4.7 |
Product class | Energy efficiency ratio (lb/kWh/cycle) | Water efficiency ratio (lb/gal/cycle) |
(A) Automatic Clothes Washers: | ||
(1 ) Top-Loading Ultra-Compact (less than 1.6 ft3 capacity) | 3.79 | 0.29 |
(2 ) Top-Loading Standard-Size (1.6 ft3 or greater capacity) 1 | 4.27 | 0.57 |
(3 ) Front-Loading Compact (less than 3.0 ft3 capacity) 2 | 5.02 | 0.71 |
(4 ) Front-Loading Standard-Size (3.0 ft3 or greater capacity) 3 | 5.52 | 0.77 |
(B) Semi-Automatic Clothes Washers | 2.12 | 0.27 |
1 The energy conservation standards in this table do not apply to top-loading standard-size clothes washers with an average cycle time less than 30 minutes.
2 The energy conservation standards in this table do not apply to front-loading clothes washers with a capacity greater than or equal to 1.6 ft3 and less than 3.0 ft3 with an average cycle time of less than 45 minutes.
3 The energy conservation standards in this table do not apply to front-loading standard-size clothes washers with an average cycle time less than 45 minutes.
Product class | Energy factor (lbs/kWh) |
i. Electric, Standard (4.4 ft3 or greater capacity) | 3.01 |
ii. Electric, Compact (120V) (less than 4.4 ft3 capacity) | 3.13 |
iii. Electric, Compact (240V) (less than 4.4 ft3 capacity) | 2.90 |
iv. Gas | 2.67 |
Product class | Combined energy factor (lbs/kWh) |
(i) Vented Electric, Standard (4.4 ft3 or greater capacity) | 3.73 |
(ii) Vented Electric, Compact (120V) (less than 4.4 ft3 capacity) | 3.61 |
(iii) Vented Electric, Compact (240V) (less than 4.4 ft3 capacity) | 3.27 |
(iv) Vented Gas | 3.30 |
(v) Ventless Electric, Compact (240V) (less than 4.4 ft3 capacity) | 2.55 |
(vi) Ventless Electric, Combination Washer-Dryer | 2.08 |
Product class | CEF D2 (lb/kWh) |
(i) Electric, Standard (4.4 ft 3 or greater capacity) * | 3.93 |
(ii) Electric, Compact (120V) (less than 4.4 ft 3 capacity) | 4.33 |
(iii) Vented Electric, Compact (240V) (less than 4.4 ft 3 capacity) | 3.57 |
(iv) Vented Gas, Standard (4.4 ft 3 or greater capacity) ** | 3.48 |
(v) Vented Gas, Compact (less than 4.4 ft 3 capacity) | 2.02 |
(vi) Ventless Electric, Compact (240V) (less than 4.4 ft 3 capacity) | 2.68 |
(vii) Ventless Electric, Combination Washer-Dryer | 2.33 |
* The energy conservation standards in this product class do not apply to Vented Electric, Standard clothes dryers with a cycle time of less than 30 minutes, when tested according to appendix D2 in subpart B of this part.
** The energy conservation standards in this product class do not apply to Vented Gas, Standard clothes dryers with a cycle time of less than 30 minutes, when tested according to appendix D2 in subpart B of this part.
Product class | Annual fuel utilization efficiency, Jan. 1, 1990 (percent) |
1. Gas wall fan type up to 42,000 Btu/h | 73 |
2. Gas wall fan type over 42,000 Btu/h | 74 |
3. Gas wall gravity type up to 10,000 Btu/h | 59 |
4. Gas wall gravity type over 10,000 Btu/h up to 12, 000 Btu/h | 60 |
5. Gas wall gravity type over 12,000 Btu/h up to 15,000 Btu/h | 61 |
6. Gas wall gravity type over 15,000 Btu/h up to 19,000 Btu/h | 62 |
7. Gas wall gravity type over 19,000 Btu/h and up to 27,000 Btu/h | 63 |
8. Gas wall gravity type over 27,000 Btu/h and up to 46,000 Btu/h | 64 |
9. Gas wall gravity type over 46,000 Btu/h | 65 |
10. Gas floor up to 37,000 Btu/h | 56 |
11. Gas floor over 37,000 Btu/h | 57 |
12. Gas room up to 18,000 Btu/h | 57 |
13. Gas room over 18,000 Btu/h up to 20,000 Btu/h | 58 |
14. Gas room over 20,000 Btu/h up to 27,000 Btu/h | 63 |
15. Gas room over 27,000 Btu/h up to 46,000 Btu/h | 64 |
16. Gas room over 46,000 Btu/h | 65 |
Product class | Annual fuel utilization efficiency, April 16, 2013 (percent) |
Gas wall fan type up to 42,000 Btu/h | 75 |
Gas wall fan type over 42,000 Btu/h | 76 |
Gas wall gravity type up to 27,000 Btu/h | 65 |
Gas wall gravity type over 27,000 Btu/h up to 46,000 Btu/h | 66 |
Gas wall gravity type over 46,000 Btu/h | 67 |
Gas floor up to 37,000 Btu/h | 57 |
Gas floor over 37,000 Btu/h | 58 |
Gas room up to 20,000 Btu/h | 61 |
Gas room over 20,000 Btu/h up to 27,000 Btu/h | 66 |
Gas room over 27,000 Btu/h up to 46,000 Btu/h | 67 |
Gas room over 46,000 Btu/h | 68 |
BLE = A/(1 + B * average total lamp arc power ^ -C) Where A, B, and C are as follows: | |||
Description | A | B | C |
Instant start and rapid start ballasts (not classified as residential ballasts) that are designed and marketed to operate: | |||
4-foot medium bipin lamps; | 0.993 | 0.27 | 0.25 |
2-foot U-shaped lamps; or | |||
8-foot slimline lamps. | |||
Programmed start ballasts (not classified as residential ballasts) that are designed and marketed to operate: | |||
4-foot medium bipin lamps; | 0.993 | 0.51 | 0.37 |
2-foot U-shaped lamps; | |||
4-foot miniature bipin standard output lamps; or | |||
4-foot miniature bipin high output lamps. | |||
Instant start and rapid start ballasts (not classified as sign ballasts) that are designed and marketed to operate 8-foot high output lamps | 0.993 | 0.38 | 0.25 |
Programmed start ballasts (not classified as sign ballasts) that are designed and marketed to operate 8-foot high output lamps | 0.973 | 0.70 | 0.37 |
Sign ballasts that are designed and marketed to operate 8-foot high output lamps | 0.993 | 0.47 | 0.25 |
Instant start and rapid start residential ballasts that are designed and marketed to operate: | |||
4-foot medium bipin lamps; | 0.993 | 0.41 | 0.25 |
2-foot U-shaped lamps; or | |||
8-foot slimline lamps. | |||
Programmed start residential ballasts that are designed and marketed to operate: | |||
4-foot medium bipin lamps or | 0.973 | 0.71 | 0.37 |
2-foot U-shaped lamps. |
Designed and marketed for operation of a maximum of | Nominal input voltage | Total nominal lamp watts | Ballast luminous efficiency | |
Low frequency ballasts | High frequency ballasts | |||
One F34T12 lamp | 120/277 | 34 | 0.777 | 0.778 |
Two F34T12 lamps | 120/277 | 68 | 0.804 | 0.805 |
Two F96T12/ES lamps | 120/277 | 120 | 0.876 | 0.884 |
Two F96T12HO/ES lamps | 120/277 | 190 | 0.711 | 0.713 |
Lamp type | Nominal lamp watts * | Minimum color rendering index | Effective date |
(i) 4-foot medium bipin | [GREATER THAN]35 W [LESS THAN EQUAL TO]35 W | 69 45 | Nov. 1, 1995. Nov. 1, 1995. |
(ii) 2-foot U-shaped | [GREATER THAN]35 W [LESS THAN EQUAL TO]35 W | 69 45 | Nov. 1, 1995. Nov. 1, 1995. |
(iii) 8-foot slimline | [GREATER THAN]65 W [LESS THAN EQUAL TO]65 W | 69 45 | May 1, 1994. May 1, 1994. |
(iv) 8-foot high output | [GREATER THAN]100 W [LESS THAN EQUAL TO]100 W | 69 45 | May 1, 1994. May 1, 1994. |
* Nominal lamp watts means the wattage at which a fluorescent lamp is designed to operate. 42 U.S.C. 6291(29)(H)
Lamp type | Correlated color temperature | Minimum average lamp efficacy lm/W |
(i) 4-foot medium bipin lamps (straight-shaped lamp with medium bipin base, nominal overall length of 48 inches, and rated wattage of 25 or more) | [LESS THAN EQUAL TO]4,500K [GREATER THAN]4,500K and [LESS THAN EQUAL TO]7,000K | 92.4 88.7 |
(ii) 2-foot U-shaped lamps (U-shaped lamp with medium bipin base, nominal overall length between 22 and 25 inches, and rated wattage of 25 or more) | [LESS THAN EQUAL TO]4,500K [GREATER THAN]4,500K and [LESS THAN EQUAL TO]7,000K | 85.0 83.3 |
(iii) 8-foot slimline lamps (instant start lamp with single pin base, nominal overall length of 96 inches, and rated wattage of 49 or more) | [LESS THAN EQUAL TO]4,500K [GREATER THAN]4,500K and [LESS THAN EQUAL TO]7,000K | 97.0 93.0 |
(iv) 8-foot high output lamps (rapid start lamp with recessed double contact base, nominal overall length of 96 inches) | [LESS THAN EQUAL TO]4,500K [GREATER THAN]4,500K and [LESS THAN EQUAL TO]7,000K | 92.0 88.0 |
(v) 4-foot miniature bipin standard output lamps (straight-shaped lamp with miniature bipin base, nominal overall length between 45 and 48 inches, and rated wattage of 25 or more) | [LESS THAN EQUAL TO]4,500K [GREATER THAN]4,500K and [LESS THAN EQUAL TO]7,000K | 95.0 89.3 |
(vi) 4-foot miniature bipin high output lamps (straight-shaped lamp with miniature bipin base, nominal overall length between 45 and 48 inches, and rated wattage of 44 or more) | [LESS THAN EQUAL TO]4,500K [GREATER THAN]4,500K and [LESS THAN EQUAL TO]7,000K | 82.7 76.9 |
Note 1 to paragraph (n)(3): For paragraphs (n)(3)(i) through (vi), rated wattage is defined with respect to fluorescent lamps and general service fluorescent lamps in § 430.2 .
Rated wattage | Lamp spectrum | Lamp diameter inches | Rated voltage of lamp | Minimum average lamp efficacy lm/W |
(i) 40-205 | Standard Spectrum | [GREATER THAN]2.5 | [GREATER THAN EQUAL TO]125 V [LESS THAN]125 V | 6.8*P0.27 5.9*P0.27 |
[LESS THAN EQUAL TO]2.5 | [GREATER THAN EQUAL TO]125 V [LESS THAN]125 V | 5.7*P0.27 5.0*P0.27 | ||
(ii) 40-205 | Modified Spectrum | [GREATER THAN]2.5 | [GREATER THAN EQUAL TO]125 V [LESS THAN]125 V | 5.8*P0.27 5.0*P0.27 |
[LESS THAN EQUAL TO]2.5 | [GREATER THAN EQUAL TO]125 V [LESS THAN]125 V | 4.9*P0.27 4.2*P0.27 |
Note 2 to paragraph (n)(4): P is equal to the rated wattage, in watts. Rated wattage is defined with respect to incandescent reflector lamps in § 430.2 .
Note 3 to paragraph (n)(4): Standard Spectrum means any incandescent reflector lamp that does not meet the definition of modified spectrum in § 430.2 .
Faucet type | Maximum flow rate (gpm (L/min)) or (gal/cycle (L/cycle)) |
Lavatory faucets | 2.2 gpm (8.3 L/min)1 2 |
Lavatory replacement aerators | 2.2 gpm (8.3 L/min) |
Kitchen faucets | 2.2 gpm (8.3 L/min) |
Kitchen replacement aerators | 2.2 gpm (8.3 L/min) |
Metering faucets | 0.25 gal/cycle (0.95 L/cycle)3 4 |
NOTE:
1 Sprayheads with independently-controlled orifices and manual controls.
The maximum flow rate of each orifice that manually turns on or off shall not exceed the maximum flow rate for a lavatory faucet.
2 Sprayheads with collectively controlled orifices and manual controls.
The maximum flow rate of a sprayhead that manually turns on or off shall be the product of (a) the maximum flow rate for a lavatory faucet and (b) the number of component lavatories (rim space of the lavatory in inches (millimeters) divided by 20 inches (508 millimeters)).
3 Sprayheads with independently controlled orifices and metered controls.
The maximum flow rate of each orifice that delivers a pre-set volume of water before gradually shutting itself off shall not exceed the maximum flow rate for a metering faucet.
4 Sprayheads with collectively-controlled orifices and metered controls.
The maximum flow rate of a sprayhead that delivers a pre-set volume of water before gradually shutting itself off shall be the product of (a) the maximum flow rate for a metering faucet and (b) the number of component lavatories (rim space of the lavatory in inches (millimeters) divided by 20 inches (508 millimeters)).
Water closet type | Maximum flush rate (gpf (Lpf)) | |
Manufactured after January 1, 1994 | Manufactured after January 1, 1997 | |
(1) Gravity flush tank water closet | 1.6 (6.0) | 1.6 (6.0) |
(2) Flushometer tank water closet | 1.6 (6.0) | 1.6 (6.0) |
(3) Electromechanical hydraulic water closet | 1.6 (6.0) | 1.6 (6.0) |
(4) Blowout bowl water closet | 3.5 (13.2) | 3.5 (13.2) |
(5) Flushometer valve water closets, other than those with blowout bowls | 1.6 (6.0) |
Product class as defined in Appendix U | Minimum efficiency (CFM/W)1 |
Very small-diameter (VSD) | D [LESS THAN EQUAL TO] 12 in.: 21. |
D [GREATER THAN] 12 in.: 3.16 D-17.04. | |
Standard | 0.65 D + 38.03. |
Hugger | 0.29 D + 34.46. |
High-speed small-diameter (HSSD) | 4.16 D + 0.02. |
1 D is the ceiling fan's blade span, in inches, as determined in Appendix U of this part.
Factor | Requirements |
Rated Wattage (Watts) & Configuration1 | Minimum Initial Lamp Efficacy (lumens per watt)2 |
Bare Lamp: | |
Lamp Power [LESS THAN]15 | 45.0 |
Lamp Power [GREATER THAN EQUAL TO]15 | 60.0 |
Covered Lamp (no reflector): | |
Lamp Power [LESS THAN]15 | 40.0 |
15[LESS THAN EQUAL TO]Lamp Power [LESS THAN]19 | 48.0 |
19[LESS THAN EQUAL TO]Lamp Power [LESS THAN]25 | 50.0 |
Lamp Power [GREATER THAN EQUAL TO]25 | 55.0 |
With Reflector: | |
Lamp Power [LESS THAN]20 | 33.0 |
Lamp Power [GREATER THAN EQUAL TO]20 | 40.0 |
Lumen Maintenance at 1,000 hours | [GREATER THAN EQUAL TO] 90.0% |
Lumen Maintenance at 40 Percent of Lifetime | [GREATER THAN EQUAL TO] 80.0% |
Rapid Cycle Stress Test | Each lamp must be cycled once for every 2 hours of lifetime. At least 5 lamps must meet or exceed the minimum number of cycles. |
Lifetime | [GREATER THAN EQUAL TO] 6,000 hours for the sample of lamps. |
1 Use rated wattage to determine the appropriate minimum efficacy requirements in this table.
2 Calculate efficacy using measured wattage, rather than rated wattage, and measured lumens to determine product compliance. Wattage and lumen values indicated on products or packaging may not be used in calculation.
Factor | Requirement |
System Efficacy Per Lamp Ballast Platform in Lumens Per Watt (lm/w) | [GREATER THAN EQUAL TO]50 lm/w for all lamps below 30 total listed lamp watts. |
[GREATER THAN EQUAL TO]60 lm/w for all lamps that are [LESS THAN EQUAL TO] 24 inches and | |
[GREATER THAN EQUAL TO]30 total listed lamp watts. | |
[GREATER THAN EQUAL TO]70 lm/w for all lamps that are [GREATER THAN] 24 inches and | |
[GREATER THAN EQUAL TO]30 total listed lamp watts. |
Lumens 1 | Minimum required efficacy (lm/W) |
(i) <120 | 50. |
(ii) [GREATER THAN EQUAL TO]120 | (74.0-29.42 * 0.9983lumens). |
1 Use the lumen output for each basic model of lamp packaged with the basic model of CFLK, each basic model of consumer-replaceable SSL packaged with the basic model of CFLK, or each basic model of non-consumer-replaceable SSL in the CFLK basic model to determine the applicable standard.
Product capacity (pints/day) | Minimum energy factor (liters/kWh) |
Up to 35.00 | 1.35 |
35.01-45.00 | 1.50 |
45.01-54.00 | 1.60 |
54.01-75.00 | 1.70 |
75.01 or more | 2.5 |
Portable dehumidifier product capacity (pints/day) | Minimum integrated energy factor (liters/kWh) |
25.00 or less | 1.30 |
25.01-50.00 | 1.60 |
50.01 or more | 2.80 |
Whole-home dehumidifier product case volume (cubic feet) | |
8.0 or less | 1.77 |
More than 8.0 | 2.41 |
Active mode | |
Nameplate output | Required efficiency (decimal equivalent of a percentage) |
Less than 1 watt | 0.5 times the Nameplate output. |
From 1 watt to not more than 51 watts | The sum of 0.09 times the Natural Logarithm of the Nameplate Output and 0.5. |
Greater than 51 watts | 0.85.S |
No-load mode | |
Nameplate output | Maximum consumption |
Not more than 250 watts | 0.5 watts. |
Class A EPS | Non-Class A EPS | |
Direct Operation EPS | Level VI: 10 CFR 430.32(w)(1)(ii) | Level VI: 10 CFR 430.32(w)(1)(ii) . |
Indirect Operation EPS | Level IV: 10 CFR 430.32(w)(1)(i) | No Standards. |
Table 1 - Energy Conservation Standards for Covered Residential Furnace Fans*
Product class | FER ** (Watts/1000 cfm) |
Non-Weatherized, Non-Condensing Gas Furnace Fan (NWG-NC) | FER = 0.044 * QMax + 182 |
Non-Weatherized, Condensing Gas Furnace Fan (NWG-C) | FER = 0.044 * QMax + 195 |
Weatherized Non-Condensing Gas Furnace Fan (WG-NC) | FER = 0.044 * QMax + 199 |
Non-Weatherized, Non-Condensing Oil Furnace Fan (NWO-NC) | FER = 0.071 * QMax + 382 |
Non-Weatherized Electric Furnace/Modular Blower Fan (NWEF/NWMB) | FER = 0.044 * QMax + 165 |
Mobile Home Non-Weatherized, Non-Condensing Gas Furnace Fan (MH-NWG-NC) | FER = 0.071 * QMax + 222 |
Mobile Home Non-Weatherized, Condensing Gas Furnace Fan (MH-NWG-C) | FER = 0.071 * QMax + 240 |
Mobile Home Electric Furnace/Modular Blower Fan (MH-EF/MB) | FER = 0.044 * QMax + 101 |
Mobile Home Non-Weatherized Oil Furnace Fan (MH-NWO) | Reserved |
Mobile Home Weatherized Gas Furnace Fan (MH-WG) ** | Reserved |
* Furnace fans incorporated into hydronic air handlers, SDHV modular blowers, SDHV electric furnaces, and CAC/HP indoor units are not subject to the standards listed in this table.
** QMax is the airflow, in cfm, at the maximum airflow-control setting measured using the final DOE test procedure at 10 CFR part 430, subpart B, appendix AA.
Product class | Product class description | Rated battery energy (Ebatt **) | Special characteristic or battery voltage | Maximum UEC (kWh/yr) (as a function of Ebatt **) |
1 | Low-Energy | [LESS THAN EQUAL TO]5 Wh | Inductive Connection * | 3.04 |
2 | Low-Energy, Low-Voltage | [LESS THAN]100 Wh | [LESS THAN]4 V | 0.1440 * Ebatt + 2.95 |
3 | Low-Energy, Medium-Voltage | 4-10 V | For Ebatt [LESS THAN]10 Wh, 1.42 kWh/y Ebatt [GREATER THAN EQUAL TO]10 Wh, 0.0255 * Ebatt + 1.16 | |
4 | Low-Energy, High-Voltage | [GREATER THAN]10 V | 0.11 * Ebatt + 3.18 | |
5 | Medium-Energy, Low-Voltage | 100-3000 Wh | [LESS THAN]20 V | 0.0257 * Ebatt + .815 |
6 | Medium-Energy, High-Voltage | [GREATER THAN EQUAL TO]20 V | 0.0778 * Ebatt + 2.4 | |
7 | High-Energy | [GREATER THAN]3000 Wh | 0.0502 * Ebatt + 4.53 |
* Inductive connection and designed for use in a wet environment (e.g. electric toothbrushes).
** Ebatt = Rated battery energy as determined in 10 CFR part 429.39(a).
Battery charger product class | Rated output power | Minimum efficiency |
10a (VFD UPSs) | 0 W [LESS THAN] Prated [LESS THAN EQUAL TO] 300 W | -1.20E-06 * P2rated + 7.17E-04 * Prated + 0.862. |
300 W [LESS THAN] Prated [LESS THAN EQUAL TO] 700 W | -7.85E-08 * P2rated + 1.01E-04 * Prated + 0.946. | |
Prated [GREATER THAN] 700 W | -7.23E-09 * P2rated + 7.52E-06 * Prated + 0.977. | |
10b (VI UPSs) | 0 W [LESS THAN] Prated [LESS THAN EQUAL TO] 300 W | -1.20E-06 * P2rated + 7.19E-04 * Prated + 0.863. |
300 W [LESS THAN] Prated [LESS THAN EQUAL TO] 700 W | -7.67E-08 * P2rated + 1.05E-04 * Prated + 0.947. | |
Prated [GREATER THAN] 700 W | -4.62E-09 * P2rated + 8.54E-06 * Prated + 0.979. | |
10c (VFI UPSs) | 0 W [LESS THAN] Prated [LESS THAN EQUAL TO] 300 W | -3.13E-06 * P2rated + 1.96E-03 * Prated + 0.543. |
300 W [LESS THAN] Prated [LESS THAN EQUAL TO] 700 W | -2.60E-07 * P2rated + 3.65E-04 * Prated + 0.764. | |
Prated [GREATER THAN] 700 W | -1.70E-08 * P2rated + 3.85E-05 * Prated + 0.876. |
Product class | AEU (kWh/yr) |
1. Built-in compact | 7.88AV + 155.8 |
2. Built-in | |
3. Freestanding compact | |
4. Freestanding |
AV = Total adjusted volume, expressed in ft3, as calculated according to appendix A of subpart B of this part.
Product class | AEU (kWh/yr) |
C-3A. Cooler with all-refrigerator - automatic defrost | 4.57AV + 130.4 |
C-3A-BI. Built-in cooler with all-refrigerator - automatic defrost | 5.19AV + 147.8 |
C-9. Cooler with upright freezers with automatic defrost without an automatic icemaker | 5.58AV + 147.7 |
C-9-BI. Built-in cooler with upright freezer with automatic defrost without an automatic icemaker | 6.38AV + 168.8 |
C-9I. Cooler with upright freezer with automatic defrost with an automatic icemaker | 5.58AV + 231.7 |
C-9I-BI. Built-in cooler with upright freezer with automatic defrost with an automatic icemaker | 6.38AV + 252.8 |
C-13A. Compact cooler with all-refrigerator - automatic defrost | 5.93AV + 193.7 |
C-13A-BI. Built-in compact cooler with all-refrigerator - automatic defrost | 6.52AV + 213.1 |
AV = Total adjusted volume, expressed in ft3, as calculated according to appendix A of subpart B of this part.
SACC: For single-speed portable air conditioners, SACC is seasonally adjusted cooling capacity in Btu/h, as determined in appendix CC of subpart B of this part. For variable-speed portable air conditioners, SACC shall be SACCFull in Btu/h, as determined in appendix CC of subpart B of this part.
General Service Incandescent Lamps
Rated lumen ranges | Minimum lifetime * (hrs) | Maximum rate wattage | Compliance date |
(A) 1490-2600 | 1,000 | 72 | 1/1/2012 |
(B) 1050-1489 | 1,000 | 53 | 1/1/2013 |
(C) 750-1049 | 1,000 | 43 | 1/1/2014 |
(D) 310-749 | 1,000 | 29 | 1/1/2014 |
* Use lifetime determined in accordance with § 429.66 of this chapter to determine compliance with this standard.
Modified Spectrum General Service Incandescent Lamps
Rated lumen ranges | Minimum lifetime 1 (hrs) | Maximum rate wattage | Compliance date |
(A) 1118-1950 | 1,000 | 72 | 1/1/2012 |
(B) 788-1117 | 1,000 | 53 | 1/1/2013 |
(C) 563-787 | 1,000 | 43 | 1/1/2014 |
(D) 232-562 | 1,000 | 29 | 1/1/2014 |
1 Use lifetime determined in accordance with § 429.66 of this chapter to determine compliance with this standard.
Factor | Requirements | |
Configuration 1 | Labeled wattage (watts) | Minimum initial lamp efficacy (lumens per watt) must be at least: |
(A) Bare Lamp: | ||
(1) Labeled Wattage <15 | 45.0 | |
(2) Labeled Wattage [GREATER THAN EQUAL TO]15 | 60.0 | |
(B) Covered Lamp (no reflector): | ||
(1) Labeled Wattage <15 | 40.0 | |
(2) 15[LESS THAN EQUAL TO] Labeled Wattage <19 | 48.0 | |
(3) 19[LESS THAN EQUAL TO] Labeled Wattage <25 | 50.0 | |
(4) Labeled Wattage [GREATER THAN EQUAL TO]25 | 55.0 |
1 Use labeled wattage to determine the appropriate efficacy requirements in this table; do not use measured wattage for this purpose.
Lamp type | Length | Standby mode operation 3 | Efficacy (lm/W) |
(1) Integrated Omnidirectional | Short (<45 inches) | No Standby Mode Operation | 123/(1.2+e-0.005*(Lumens-200 ))) + 25.9 |
(2) Integrated Omnidirectional | Long ([GREATER THAN EQUAL TO]45 inches) | No Standby Mode Operation | 123/(1.2+e-0.005*(Lumens-200 ))) + 71.7 |
(3 ) 1 Integrated Directional | All Lengths | No Standby Mode Operation | 73/(0.5+e-0.0021*(Lumens+1000 ))) - 47.2 |
(4 ) 2 Non-integrated Omnidirectional | Short (<45 inches) | No Standby Mode Operation | 122/(0.55+e-0.003*(Lumens+250 ))) - 83.4 |
(5 ) 1 Non-integrated Directional | All Lengths | No Standby Mode Operation | 67/(0.45+e-0.00176*(Lumens+1310 ))) - 53.1 |
(6) Integrated Omnidirectional | Short (<45 inches) | Standby Mode Operation | 123/(1.2+e-0.005*(Lumens-200 ))) + 17.1 |
(7 ) 1 Integrated Directional | All Lengths | Standby Mode Operation | 73/(0.5+e-0.0021*(Lumens+1000 )) - 50.9 |
(8) Non-integrated Omnidirectional | Long ([GREATER THAN EQUAL TO]45 inches) | No Standby Mode Operation | 123/(1.2+e-0.005*(Lumens-200 ))) + 93.0 |
1 This lamp type comprises of directional lamps. A directional lamp is a lamp that meets the definition of reflector lamp as defined in § 430.2 .
2 This lamp type comprises of, but is not limited to, lamps that are pin base compact fluorescent lamps ("CFLs") and pin base light-emitting diode ("LED") lamps designed and marketed as replacements of pin base CFLs.
3 Indicates whether or not lamps are capable of operating in standby mode operation.
Metrics | Requirements for MBCFLs manufactured on or after January 1, 2006 | Requirements for MBCFLs manufactured on or after July 25, 2028 |
(i) Lumen Maintenance at 1,000 Hours | [GREATER THAN EQUAL TO]90.0% | [GREATER THAN EQUAL TO]90.0%. |
(ii) Lumen Maintenance at 40 Percent of Lifetime1 | [GREATER THAN EQUAL TO]80.0% | [GREATER THAN EQUAL TO]80.0%. |
(iii) Rapid Cycle Stress Test | At least 5 lamps must meet or exceed the minimum number of cycles | At least 5 lamps must meet or exceed the minimum number of cycles. |
All MBCFLs: Cycle once per every two hours of lifetime 1 | MBCFLs with start time >100 ms: Cycle once per hour of lifetime 1 or a maximum of 15,000 cycles. MBCFLs with a start time of [LESS THAN EQUAL TO]100 ms: Cycle once per every two hours of lifetime.1 | |
(iv) Lifetime 1 | [GREATER THAN EQUAL TO]6,000 hours | [GREATER THAN EQUAL TO]10,000 hours. |
(v) Start time | No requirement | The time needed for a MBCFL to remain continuously illuminated must be within: {1} one second of application of electrical power for lamp with standby mode power {2} 750 milliseconds of application of electrical power for lamp without standby mode power. |
1 Lifetime refers to lifetime of a compact fluorescent lamp as defined in § 430.2 .
Product capacity | IEF (PM 2.5 CADR/W) |
(i) 10 [LESS THAN EQUAL TO]PM 2.5 CADR <100 | 1.7 |
(ii) 100 [LESS THAN EQUAL TO]PM 2.5 CADR <150 | 1.9 |
(iii) PM 2.5 CADR [GREATER THAN EQUAL TO]150 | 2.0 |
Product capacity | IEF (PM 2.5 CADR/W) |
(i) 10 [LESS THAN EQUAL TO]PM 2.5 CADR <100 | 1.9 |
(ii) 100 [LESS THAN EQUAL TO]PM 2.5 CADR <150 | 2.4 |
(iii) PM 2.5 CADR [GREATER THAN EQUAL TO]150 | 2.9 |