Table 1 to Paragraph (b)(1)
Category | Equipment subcategory | Required represented values |
Single-Package unit | Single-Package AC (including Space-Constrained) | Every individual model distributed in commerce. |
Single-Package HP (including Space-Constrained) | ||
Outdoor Unit and Indoor Unit (Distributed in Commerce by OUM (Outdoor Unit Manufacturer)) | Single-Split-System AC with Single-Stage or Two-Stage Compressor (including Space-Constrained and Small-Duct, High Velocity Systems (SDHV)) | Every individual combination distributed in commerce. Each model of outdoor unit must include a represented value for at least one coil-only individual combination that is distributed in commerce and which is representative of the least efficient combination distributed in commerce with that particular model of outdoor unit. For that particular model of outdoor unit, additional represented values for coil-only and blower-coil individual combinations are allowed, if distributed in commerce. |
Single-Split-System AC with Other Than Single-Stage or Two-Stage Compressor (including Space-Constrained and SDHV) | Every individual combination distributed in commerce, including all coil-only and blower coil combinations. | |
Single-Split-System HP (including Space-Constrained and SDHV) | Every individual combination distributed in commerce. | |
Multi-Split, Multi-Circuit, or Multi-Head Mini-Split Split System-non-SDHV (including Space-Constrained) | For each model of outdoor unit, at a minimum, a non-ducted "tested combination." For any model of outdoor unit also sold with models of ducted indoor units, a ducted "tested combination." When determining represented values on or after the compliance date of any amended energy conservation standards, the ducted "tested combination" must comprise the highest static variety of ducted indoor unit distributed in commerce (i.e., conventional, mid-static, or low-static). Additional representations are allowed, as described in paragraph (d)(3) of this section. | |
Multi-Split, Multi-Circuit, or Multi-Head Mini-Split Split System-SDHV | For each model of outdoor unit, an SDHV "tested combination." Additional representations are allowed, as described in paragraph (d)(3) of this section. | |
Indoor Unit Only Distributed in Commerce by ICM (Independent Coil Manufacturer) | Single-Split-System Air Conditioner (including Space-Constrained and SDHV) | Every individual combination distributed in commerce. |
Single-Split-System Heat Pump (including Space-Constrained and SDHV) | ||
Multi-Split, Multi-Circuit, or Multi-Head Mini-Split Split System-SDHV | For a model of indoor unit within each basic model, a SDHV "tested combination." Additional representations are allowed, as described in section (d)(3)(ii) of this section. | |
Outdoor Unit with no Match | Every model of outdoor unit distributed in commerce (tested with a model of coil-only indoor unit as specified in paragraph (c)(2) of this section). |
and, x is the sample mean; n is the number of samples; and xi is the ith sample; or,
And x is the sample mean; s is the sample standard deviation; n is the number of samples; and t0.90 is the t statistic for a 90 percent one-tailed confidence interval with n-1 degrees of freedom (from appendix A of this subpart). Round represented values of SEER2 and HSPF2 to the nearest 0.05.
and, x is the sample mean; n is the number of samples; and xi is the ith sample; or,
And x is the sample mean; s is the sample standard deviation; n is the number of samples; and t0.90 is the t statistic for a 90 percent one-tailed confidence interval with n-1 degrees of freedom (from appendix D of this part).
10 C.F.R. §429.67