10 C.F.R. § 429.54

Current through November 30, 2024
Section 429.54 - Metal halide lamp ballasts and fixtures
(a)Sampling plan for selection of units for testing.
(1) The requirements of § 429.11 are applicable to metal halide lamp ballasts; and
(2) For each basic model of metal halide lamp ballast selected for testing, a sample of sufficient size, not less than four, shall be selected at random and tested to ensure that:
(i) Any represented value of estimated energy efficiency calculated as the measured output power to the lamp divided by the measured input power to the ballast (Pout/Pin), of a basic model is less than or equal to the lower of:
(A) The mean of the sample, where:

View Image

Or,

(B) The lower 99-percent confidence limit (LCL) of the true mean divided by 0.99.

View Image

And x is the sample mean; s is the sample standard deviation; n is the number of samples; and t0.99 is the t statistic for a 99% two-tailed confidence interval with n-1 degrees of freedom (from appendix A).

(b)Certification reports.
(1) The requirements of § 429.12 are applicable to metal halide lamp ballasts; and
(2) Pursuant to § 429.12(b)(13) , a certification report shall include the following public product-specific information: The minimum ballast efficiency in percent (%), the lamp wattage in watts (W), and the type of ballast (e.g., pulse-start, magnetic probe-start, and non-pulse start electronic).

10 C.F.R. §429.54

76 FR 12451 , Mar. 7, 2011; 76 FR 24780 , May 2, 2011; 76 FR 46202 , Aug. 2, 2011