10 C.F.R. § 429.24

Current through October 31, 2024
Section 429.24 - [Effective until 12/23/2024] Pool heaters
(a)Sampling plan for selection of units for testing.
(1) The requirements of § 429.11 are applicable to pool heaters; and
(2) For each basic model of pool heater a sample of sufficient size shall be randomly selected and tested to ensure that any represented value of the thermal efficiency or other measure of energy consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:

View Image

(i) The mean of the sample, where:

Or,

(ii) The lower 971/2 percent confidence limit (LCL) of the true mean divided by 0.95, where:

View Image

(b)Certification reports.
(1) The requirements of § 429.12 are applicable to pool heaters; and
(2) Pursuant to § 429.12(b)(13) , a certification report shall include the following public product-specific information: The thermal efficiency in percent (%) and the input capacity in British thermal units per hour (Btu/h).

10 C.F.R. §429.24

76 FR 12451 , Mar. 7, 2011; 76 FR 24769 , May 2, 2011