NOTE: Explosives not subject to mass detonation may be processed in buildings located in accordance with other intraline distance tables of recognized authority such as DOD or ATF Tables 55.219 and 55.222 through 55.224, with footnotes.
Intra Plant Distance Table For Use Only Within Confines of Explosives Manufacturing Plants
Pounds Over | Pounds Not Over | Distance in Feet When Building is Barricaded* | Pounds Over | Pounds Not Over | Distance in Feet When Building is Barricaded* |
2 | 5 | 16 | 12,000 | 14,000 | 220 |
5 | 10 | 20 | 14,000 | 16,000 | 230 |
10 | 20 | 25 | 16,000 | 18,000 | 238 |
20 | 30 | 28 | 18,000 | 20,000 | 245 |
30 | 40 | 31 | 20,000 | 25,000 | 265 |
40 | 50 | 34 | 25,000 | 30,000 | 280 |
50 | 75 | 38 | 30,000 | 35,000 | 295 |
75 | 100 | 42 | 35,000 | 40,000 | 310 |
100 | 125 | 45 | 40,000 | 45,000 | 320 |
125 | 150 | 48 | 45,000 | 50,000 | 330 |
150 | 200 | 53 | 50,000 | 55,000 | 340 |
200 | 250 | 57 | 55,000 | 60,000 | 350 |
250 | 300 | 60 | 60,000 | 65,000 | 360 |
300 | 400 | 66 | 65,000 | 70,000 | 370 |
400 | 500 | 71 | 70,000 | 75,000 | 380 |
500 | 600 | 76 | 75,000 | 80,000 | 390 |
600 | 700 | 80 | 80,000 | 85,000 | 395 |
700 | 800 | 84 | 85,000 | 90,000 | 400 |
800 | 900 | 87 | 90,000 | 95,000 | 410 |
900 | 1,000 | 90 | 95,000 | 100,000 | 420 |
1,000 | 1,200 | 96 | 100,000 | 110,000 | 430 |
1,200 | 1,400 | 101 | 110,000 | 120,000 | 445 |
1,400 | 1,600 | 106 | 120,000 | 130,000 | 455 |
1,600 | 1,800 | 110 | 130,000 | 140,000 | 465 |
1,800 | 2,000 | 113 | 140,000 | 150,000 | 475 |
2,000 | 2,500 | 122 | 150,000 | 160,000 | 485 |
2,500 | 3,000 | 130 | 160,000 | 170,000 | 495 |
3,000 | 4,000 | 143 | 170,000 | 180,000 | 505 |
4,000 | 5,000 | 154 | 180,000 | 190,000 | 515 |
5,000 | 6,000 | 164 | 190,000 | 200,000 | 525 |
6,000 | 7,000 | 172 | 200,000 | 210,000 | 535 |
7,000 | 8,000 | 180 | 210,000 | 230,000 | 555 |
8,000 | 9,000 | 190 | 230,000 | 250,000 | 575 |
9,000 | 10,000 | 200 | 250,000 | 275,000 | 600 |
10,000 | 12,000 | 210 | 275,000 | 300,000 | 635 |
* When a building or magazine containing explosives is not barricaded, the distances shown in this Table should be doubled.
Cal. Code Regs. Tit. 8, § 5327
2. Amendment of section and new NOTE filed 7-11-2003; operative 8-10-2003 (Register 2003, No. 28).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
2. Amendment of section and new Note filed 7-11-2003; operative 8-10-2003 (Register 2003, No. 28).