Cal. Code Regs. tit. 8 § 6110

Current through Register 2024 Notice Reg. No. 44, November 1, 2024
Section 6110 - Bulkheads and Screens
(a) Intermediate bulkheads with locks or intermediate safety screens or both shall be required where there is the danger of rapid flooding.
(b) In tunnels 16 feet or more in diameter, hanging walkways shall be provided from the face to the air lock, as high in the tunnel as practicable, with at least 6 feet of head room. Walkways shall be constructed of noncombustible material. Standard railing shall be securely installed throughout the length of all walkways on open sides. Where walkways are ramped under safety screens, the walkway surface shall be skidproofed by cleats or equivalent means.
(c) Bulkheads used to contain compressed air shall be tested, where practicable, to prove their ability to resist the highest air pressure which may be expected to be used.

Cal. Code Regs. Tit. 8, § 6110

1. New section filed 4-4-2006; operative 5-4-2006 (Register 2006, No. 14).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.

1. New section filed 4-4-2006; operative 5-4-2006 (Register 2006, No. 14).