Section 4955 - Hydraulic Relief Valves

Hydraulic relief valves shall have pressure settings of sufficient magnitude to provide the capabilities of operations under 110% of rated loading conditions. Relief valve settings shall be specified and no change in relief valve setting shall be made without the consent of the certified agent. Gauge ports shall be provided in each hydraulic circuit for checking certified agent's specified pressure settings.

Cal. Code Regs. Tit. 8, § 4955

1. Amendment filed 8-29-86; effective thirtieth day thereafter (Register 86, No. 39).

Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.