Inserted Perpendicular to Grain of the Wood, in Pounds per Linear Inch of Penetration into the Main Member
Kind of wood | Size of nail | |||||||||
6d | 8d | 10d | 12d | 16d | 20d | 30d | 40d | 50d | 60d | |
Douglas Fir or Southern Pine or Redwood.......................... | 27 | 29 | 35 | 35 | 39 | 48 | 52 | 56 | 61 | 67 |
Other species.......................... | As determined by the enforcing agency |
For wood to wood joints the spacing center-to-center shall be not less than the required penetration.
Edge and end distances shall be not less than one-half of the required penetration.
Holes for nails, where necessary to prevent splitting, shall be bored of a diameter smaller than that of the nails.
PLATE B-31 BOLTS
Safe loads in pounds for bolts in double shear and in seasoned lumber of the following species: cypress, southern; Douglas fir (coast and inland region); larch, wester; pine, southern yellow; in joints consisting of three members in which the side members are one-half the thickness of the main member, shall not exceed values set forth in Plates B-31-a, -b.
Cal. Code Regs. Tit. 8, div. 1, ch. 4, subch. 4, app B, Plate B-30-b