Cal. Code Regs. tit. 25 § 1472

Current through Register 2024 Notice Reg. No. 50, December 13, 2024
Section 1472 - Awning-Foundations

Concrete slabs less than three and one-half (3 1/2) inches thick may be considered to have an allowable load bearing capacity of three-hundred-fifty (350) pounds per column. The enforcement agency may accept a loading not to exceed five-hundred (500) pounds per column, provided the slab is not less than three and one-half (3 1/2) inches thick and in good condition. The weight of individual poured concrete footings shall be one and one-half (1 1/2) times the calculated uplift force. The weight of concrete shall be assumed to be not more than one hundred forty-five (145) pounds-per-cubic-foot.

Cal. Code Regs. Tit. 25, § 1472

1. Amendment filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).

Note: Authority cited: Section 18300, Health and Safety Code. Reference: Section 18552, Health and Safety Code.

1. Amendment filed 7-6-2004; operative 7-6-2004 pursuant to Government Code section 11343.4 (Register 2004, No. 28).