Storage tanks used to store pumpout waste shall:
(a) Be designed and constructed to allow for complete emptying of contents into a disposal system or waste haulers tank.(b) Be equipped with a means of determining the amount of sewage in the tank.(c) Be equipped with a means of preventing backflow from the storage tank into the pumpout system.(d) Be designed and constructed to prevent overflow or spillage.(e) Be designed and installed to protect against a 1-in-100 year flood.(f) Be constructed of material capable of withstanding solar radiation and chemical action of freshwater, saltwater, chemical additives and sewage without excessive deterioration.(g) Be designed and constructed such that the sewage enters the tank above maximum storage level.Cal. Code Regs. Tit. 23, § 2822
1. New NOTE filed 10-1-85; effective thirtieth day thereafter (Register 85, No. 40). Note: Authority cited: Sections 775, 776, 777 and 778, Harbors and Navigation Code. Reference: Sections 775, 776, 777 and 778, Harbors and Navigation Code.
1. New NOTE filed 10-1-85; effective thirtieth day thereafter (Register 85, No. 40).