Cal. Code Regs. Tit. 22, div. 4.5, ch. 18, app VI

Current through Register 2024 Notice Reg. No. 45, November 8, 2024
Appendix VI - Recommended Technologies to Achieve Deactivation of Characteristics in Section 66268.42

The treatment standard for many characteristic wastes is stated in the section 66268.40 Table of Treatment Standards as "Deactivation and meet UTS." USEPA has determined that many technologies, when used alone or in combination, can achieve the deactivation portion of the treatment standard. Characteristic wastes that are not managed in a facility regulated by the federal Clean Water Act (CWA) or in a federal CWA-equivalent facility, and that also contain underlying hazardous constituents (see section 66260.10) shall be treated not only by a "deactivating" technology to remove the characteristic, but also to achieve the universal treatment standards (UTS) for underlying hazardous constituents. The following appendix presents a partial list of technologies, utilizing the five letter technology codes established in section 66268.42 Table 1, that may be useful in meeting the treatment standard. Use of these specific technologies is not mandatory and does not preclude direct reuse, recovery, and/or the use of other pretreatment technologies, provided deactivation is achieved and underlying hazardous constituents are treated to achieve the UTS.

Waste Code/Subcategory

Nonwastewaters

Wastewaters

D001 Ignitable Liquids basedRORGSn.a.
on 66261.21(a)(1) - Low TOCINCIN
Nonwastewater SubcategoryWETOX
(containing 1% to <10% TOC)CHOXD
BIODG
D001 Ignitable Liquids basedn.a.RORGS
on 66261.21(a)(1) - IgnitableINCIN
Wastewater SubcategoryWETOX
(containing <1% TOC)CHOXD
BIODG
D001 Compressed Gases based onRCGASn.a.
66261.21(a)(3)INCIN
FSUBS
ADGAS fb. INCIN ADGAS fb. (CHOXD; or CHRED)
D001 Ignitable Reactives basedWTRRXn.a.
on 66261.21 (a)(2)CHOXD
CHRED
STABL
INCIN
D001 Ignitable Oxidizers basedCHREDCHRED
on 66261.21(a)(4)INCININCIN
D002 Acid Subcategory based onRCORRNEUTR
66261.22(a)(1) with pH lessNEUTRINCIN
than or equal to 2INCIN
D002 Alkaline SubcategoryNEUTRNEUTR
based on 66261.22(a)(1) withINCININCIN
pH greater than or equal to 12.5
D002 Other Corrosives based onCHOXDCHOXD
66261.22(a)(2)CHREDCHRED
INCININCIN
STABL
D003 Water Reactives based onINCINn.a.
66261.23(a)(2), (3), and (4)WTRRX
CHOXD
CHRED
D003 Reactive Sulfides basedCHOXDCHOXD
on 66261.23(a)(5)CHREDCHRED
INCINBIODG
STABLINCIN
D003 Explosives based onINCININCIN
66261.23(a)(6), (7), and (8)CHOXDCHOXD
CHREDCHRED
BIODG
CARBN
D003 Other Reactives based onINCININCIN
66261.23(a)(1)CHOXDCHOXD
CHREDCHRED
BIODG
CARBN
K044 Wastewater treatmentCHOXDCHOXD
sludges from the manufacturingCHREDCHRED
and processing of explosivesINCINBIODG
CARBN
INCIN
K045 Spent carbon from theCHOXDCHOXD
treatment of wastewatersCHREDCHRED
containing explosivesINCINBIODG
CARBN
INCIN
K047 Pink/red water from TNTCHOXDCHOXD
operationsCHREDCHRED
INCINBIODG
CARBN
INCIN

NOTE: "n.a." stands for "not applicable"; "fb." stands for "followed by".

Cal. Code Regs. Tit. 22, div. 4.5, ch. 18, app VI

Note: Authority cited: Sections 208, 25150, 25159 and 25179.6, Health and Safety Code. Reference: Sections 25150, 25159, 25159.5 and 25179.6, Health and Safety Code; 40 CFR Part 268 Appendix VI.