where:
n=number of carcinogenic metals
AFR=actual feed rate to the device for metal "i"
FRSL=feed rate screening limit provided by appendix I of this chapter for metal "i".
TESH=Ha+H1-Tr
where:
Ha=Actual physical stack height.
H1=Plume rise as determined from appendix VI of this chapter as a function of stack flow rate and stack gas exhaust temperature.
Tr=Terrain rise within five kilometers of the stack.
K=HVT
Where:
K = a parameter accounting for relative influence of stack height and plume rise;
H = physical stack height (meters);
V = stack gas flow rate (m3/second); and
T = exhaust temperature (°K).
The stack with the lowest value of K is the worst-case stack.
where:
n=number of carcinogenic metals
AER=actual emission rate for metal "i"
ERSL=emission rate screening limit provided by appendix I of this chapter for metal "i".
where: n=number of carcinogenic metals
Cal. Code Regs. Tit. 22, § 66266.106
2. Amendment of subsections (g) and (g)(2) filed 10-13-98; operative 11-12-98 (Register 98, No. 42).
3. Change without regulatory effect amending subsections (b)(1)(A) and (b)(2) filed 7-1-2004 pursuant to section 100, title 1, California Code of Regulations (Register 2004, No. 27).
Note: Authority cited: Sections 25150, 25159, 25159.5, 25245, 58004 and 58012, Health and Safety Code. Reference: Sections 25159 and 25159.5, Health and Safety Code; and 40 CFR Section 266.106.
2. Amendment of subsections (g) and (g)(2) filed 10-13-98; operative 11-12-98 (Register 98, No. 42).
3. Change without regulatory effect amending subsections (b)(1)(A) and (b)(2) filed 7-1-2004 pursuant to section 100, title 1, California Code of Regulations (Register 2004, No. 27).