Current through Register 2024 Notice Reg. No. 45, November 8, 2024
Section 66265.347 - Monitoring and Inspections(a) The owner or operator shall conduct, as a minimum, the following monitoring and inspections when incinerating hazardous waste. (1) Existing instruments which relate to combustion and emission control shall be monitored at least every 15 minutes. Appropriate corrections to maintain steady state combustion conditions shall be made immediately either automatically or by the operator. Instruments which relate to combustion and emission control would normally include those measuring waste feed, auxiliary fuel feed, air flow, incinerator temperature, scrubber flow, scrubber pH, and relevant level controls.(2) The complete incinerator and associated equipment (pumps, valves, conveyors, pipes, etc.) shall be inspected at least daily for leaks, spills, and fugitive emissions, and all emergency shutdown controls and system alarms must be checked to assure proper operation.Cal. Code Regs. Tit. 22, § 66265.347
1. New section filed 5-24-91; operative 7-1-91 (Register 91, No. 22). Note: Authority cited: Sections 208 and 25159, Health and Safety Code. Reference: Sections 25159.5 and 25200, Health and Safety Code; 40 CFR Section 265.347.
1. New section filed 5-24-91; operative 7-1-91 (Register 91, No. 22).