RULE A-5 ENFORCEMENT PROCEDURES
RULE H-1 CLASS II DISPOSAL AND CLASS II COMMERCIAL DISPOSAL WELL PERMIT APPLICATION PROCEDURES
The following calculation is included only as an example, and for informational and demonstrative purposes only. For purposes of this example, assume the well is in Columbia County, the total depth to the injection formation is 2,500 feet, the specific gravity is 1.085, and the injection tubing friction loss is 250 psi. Using the formula provided above, the maximum permitted injection pressure for the well would be 1,642 psig, calculated as follows:
Step 1: 0.9 x [(1.1 psi/ft x 2500 ft) - [0.433psi/ft x 2500 ft) x 1.085 (specific gravity)] + 250 tubing friction loss]
Step 2: 0.9 x [2750 psi - 1175 + 250 tubing friction loss]
Step 3: 0.9 x [1825]
Step 4: Result = 1642 psig
Sections | Township | Range |
ALL | 4N | 13W |
ALL | 5N | 12W |
ALL | 5N | 13W |
ALL | 5N | 14W |
ALL | 6N | 12W |
ALL | 6N | 13W |
ALL | 7N | 11W |
ALL | 7N | 12W |
ALL | 7N | 13W |
ALL | 8N | 11W |
ALL | 8N | 12W |
ALL | 8N | 13W |
ALL | 9N | 10W |
ALL | 9N | 11W |
ALL | 9N | 12W |
ALL | 10N | 10W |
ALL | 10N | 11W |
ALL | 11N | 10W |
ALL | 11N | 11W |
1-12, 14-23, 27-33 | 4N | 12W |
1-30, 35-36 | 4N | 14W |
1-2, 10-15, 23-25 | 4N | 15W |
4-9, 17-20, 30-31 | 5N | 11W |
25, 35-36 | 5N | 15W |
6 | 6N | 10W |
1-23, 26-34 | 6N | 11W |
1-4, 9-36 | 6N | 14W |
24-25, 36 | 6N | 15W |
3-9, 16-20, 29-31 | 7N | 10W |
1, 11-14, 22-27, 34-36 | 7N | 14W |
6-7 | 8N | 9W |
1-24, 26-35 | 8N | 10W |
25, 36 | 8N | 14W |
3-10, 15-21, 29-32 | 9N | 9W |
1-5, 7-36 | 9N | 13W |
1-23, 27-34 | 10N | 9W |
1-3, 9-17, 19-36 | 10N | 12W |
25, 33, 34, 36 | 10N | 13W |
17-22, 27-35 | 11N | 9W |
13, 23-27, 34-36 | 11N | 12W |
178.00.11 Ark. Code R. 004