Ariz. Admin. Code § 9-7-201

Current through Register Vol. 30, No. 50, December 13, 2024
Section R9-7-201 - Exemptions
A. Electronic equipment that produces X-radiation incidental to its operation for other purposes is exempt from the registration and notification requirements of this Article, provided that an exposure rate, from any accessible surface, averaged over an area of 10 centimeters squared (1.55 inches squared) does not exceed 5 microsieverts (0.5 milliroentgen) per hour at 5 centimeters (2.0 inches).
B. The production, testing, or factory servicing of the electronic equipment in subsection (A) is not exempt from the requirements of this Article.
C. Radiation machines in storage or in transit to or from storage are exempt from the requirements of this Article.
D. Radiation machines rendered incapable of producing radiation are exempt from the requirements of this Article.

Ariz. Admin. Code § R9-7-201

New Section R9-7-201 recodified from R12-1-201, at 24 A.A.R. 813, effective March 22, 2018 (Supp. 18-1).