Current through Register Vol. 30, No. 50, December 13, 2024
Section R18-5-246 - Air Blower and Air Induction Systems for Public and Semipublic SpasAn air blower system or air induction system for a public or semipublic spa shall comply with the following requirements:
1. The system shall prevent water backflow which could cause an electrical shock hazard.2. Air intake sources shall not introduce water, dirt, or contaminants into the spa.3. The system shall be properly sized for a commercial spa application.4. If the air blower is installed within an enclosure or indoors, then adequate ventilation shall be provided.5. Integral air passages shall be pressure tested and shall provide structural integrity to a value of 1 1/2 times the intended working pressure.Ariz. Admin. Code § R18-5-246
Adopted effective February 19, 1998 (Supp. 98-1).