Current through Register Vol. 30, No. 45, November 8, 2024
Table 1 - Minimum Number of Samples Exceeding the Numeric Standard MINIMUM NUMBER OF SAMPLES EXCEEDING THE NUMERIC STANDARD |
Number of Samples | Number of Samples Exceeding Standard | Number of Samples | Number of Samples Exceeding Standard | Number of Samples | Number of Samples Exceeding Standard |
From | To | From | To | From | To |
10 | 15 | 3 | 173 | 181 | 22 | 349 | 357 | 41 |
16 | 23 | 4 | 182 | 190 | 23 | 358 | 367 | 42 |
24 | 31 | 5 | 191 | 199 | 24 | 368 | 376 | 43 |
32 | 39 | 6 | 200 | 208 | 25 | 377 | 385 | 44 |
40 | 47 | 7 | 209 | 218 | 26 | 386 | 395 | 45 |
48 | 56 | 8 | 219 | 227 | 27 | 396 | 404 | 46 |
57 | 65 | 9 | 228 | 236 | 28 | 405 | 414 | 47 |
66 | 73 | 10 | 237 | 245 | 29 | 415 | 423 | 48 |
74 | 82 | 11 | 246 | 255 | 30 | 424 | 432 | 49 |
83 | 91 | 12 | 256 | 264 | 31 | 433 | 442 | 50 |
92 | 100 | 13 | 265 | 273 | 32 | 443 | 451 | 51 |
101 | 109 | 14 | 274 | 282 | 33 | 452 | 461 | 52 |
110 | 118 | 15 | 283 | 292 | 34 | 462 | 470 | 53 |
119 | 126 | 16 | 293 | 301 | 35 | 471 | 480 | 54 |
127 | 136 | 17 | 302 | 310 | 36 | 481 | 489 | 55 |
137 | 145 | 18 | 311 | 320 | 37 | 490 | 499 | 56 |
146 | 154 | 19 | 321 | 329 | 38 | 500 | | 57 |
155 | 163 | 20 | 330 | 338 | 39 | | | |
164 | 172 | 21 | 339 | 348 | 40 | | | |
2. When there are less than ten samples, the Department shall place a surface water or segment on the Planning List following subsection (B), if three or more temporally independent samples exceed the following surface water quality standards:a. The surface water quality standard for a pollutant listed in 18 A.A.C. 11, Article 1, Appendix A, Table 1, except for nitrate or nitrate/nitrite;b. The surface water quality standard for temperature or the single sample maximum water quality standard for suspended sediment concentration, nitrogen, and phosphorus in R18-11-109;c. The surface water quality standard for radiochemicals in R18-11-109(G);d. The surface water quality standard for dissolved oxygen under R18-11-109(E);e. The surface water quality standard for pH under R18-11-109(B); orf. The following surface water quality standards in R18-11-112: i. Single sample maximum standards for nitrogen and phosphorus,ii. All metals except chromium, or3. The Department shall place a surface water or segment on the Planning List if information in subsections (B)(2)(c), (B)(2)(d), and (B)(2)(e) indicates that a narrative water quality standard violation exists, but no narrative implementation procedure required under A.R.S. § 49-232(F) exists to support use of the information for listing. D. 303(d) List. 1. When evaluating a surface water or segment for placement on the 303(d) List.a. Consider at least 20 spatially or temporally independent samples collected over three or more temporally independent sampling events; andb. Determine numeric water quality standards exceedances. The Department shall:i. Place a surface water or segment on the 303(d) List, following subsection (B), if the number of exceedances of a surface water quality standard is greater than or equal to the number listed in Table 2, which provides the number of exceedances that indicate a minimum of a 10 percent exceedance frequency with a minimum of a 90 percent confidence level using a binomial distribution, for a given sample size; orii. For sample datasets exceeding those shown in Table 2, calculate the number of exceedances using the following equation: (X[GREATOR THAN EQUAL TO]x| n, p) where n = number of samples; p = exceedance probability of 0.1; x = smallest number of exceedances required for listing with "n" samples; and confidence level [GREATOR THAN EQUAL TO] 90 percent. Ariz. Admin. Code tit. 18, ch. 11, art. 6, tbl. 1