18 Alaska Admin. Code § 72.640

Current through October 17, 2024
Section 18 AAC 72.640 - Waiver
(a) If the department determines that a waiver of a requirement of 18 AAC 72.601 - 18 AAC 72.660 will adequately protect public health, private water systems, and the environment, the department may waive or modify that requirement on a site-specific basis. The review of separation distance waivers to a public water system, or any components of one, falls under the requirements of 18 AAC 80.
(b) A request to reduce a separation distance required under 18 AAC 72.100 or 18 AAC 72.620 must be submitted in a report that specifies each waiver being sought. The report must
(1) be sealed by a registered engineer;
(2) justify the lesser distance and explain how the lesser distance does not threaten public health, public and private water systems, or the environment;
(3) describe soil classifications, groundwater conditions, surface topography, geology, and other environmental conditions that would assist the department in determining whether a lesser separation distance is protective; and
(4) include a set of plans showing
(A) a site plan with
(i) the area's topography and groundwater flow direction;
(ii) the location of surface water in the area;
(iii) existing or potential sources of contamination in the area; and
(iv) existing or proposed public and private drinking water sources in the area; and
(B) details of the existing or proposed alternative onsite wastewater system construction that will mitigate potential contamination of surface water, groundwater, and existing or proposed private drinking water sources;
(5) if the separation distance reduction is to a private water system, provide information on the construction of the existing or proposed water system; and
(6) include other information the department determines to be necessary to assess the effect of a lesser separation distance upon public health, private water systems, and the environment.
(c) A request for modification of the construction requirements for an alternative wastewater system must include a report that specifies each variation being sought. The report must
(1) be sealed by a registered engineer;
(2) justify the waiver or modification of the specific construction requirement based on site-specific conditions relevant to the request;
(3) include calculations, engineered plans of the system design, and other information that would assist the department in determining whether the waiver or modification requested will adversely impact the system performance and be protective of public health, public and private water systems, and the environment; and
(4) include other information the department determines to be necessary to assess the effect of the waiver or modification requested.
(d) The department will base its decision under this section on information submitted to justify the waiver or modification, the risk to public health, the risk to the environment, the protection of surface water, groundwater, and existing or proposed drinking water sources, and the impact on alternative wastewater system performance. As necessary, the department will require i changes to the system construction as a condition of approval.
(e) A request for a waiver or modification under this section must be accompanied by the applicable fee required under 18 AAC 72.955.

18 AAC 72.640

Eff. 10/1/2023, Register 247, October 2023

Authority:AS 44.46.020

AS 44.46.025

AS 46.03.020

AS 46.03.050

AS 46.03.100

AS 46.03.710