Section 17 AAC 15.183 - Underground utility accommodation on runways

An underground facility crossing of a runway must be installed by boring, coring, or jacking under the runway surface. Wet-boring is prohibited. The department may allow trenched or open-cut construction where untrenched construction is not practical. An underground facility crossing in a department right-of-way must conform to the specifications set out in any special provisions of the utility permit.