WIND ZONE II HURRICANE ZONE | ||
*Length of Mobile Home (ft) | **No. of Vertical Ties | No. of Diagonal Ties |
0-40 | 5 | 5 |
41 - 60 | 7 | 7 |
61 - 90 | 9 | 9 |
WIND ZONE I NON-HURRICANE ZONE | |
* * * *No. of Vertical Ties | ***No. of Diagonal Ties |
0 | 4 |
0 | 6 |
0 | 8 |
*Length of mobile home (as used in this table) means length excluding draw bar.
**The federal manufactured home construction and safety standards require all manufactured homes designed to be located in wind zones II and III to have a vertical tie installed at each diagonal tie location.
***If pier height is over 24", an additional diagonal tie must be added for every additional 12" or a portion thereof.
****Manufactured homes that do not have a HUD label must have three (3) vertical ties per side in zone 1.
Ala. Admin. Code r. 535-X-13-.07
Author: Jim Sloan
Statutory Authority:Code of Ala. 1975, §§ 24-4A-3, 24-5-31, 24-5-32, 24-6-4.