Ex Parte EidenschinkDownload PDFPatent Trials and Appeals BoardJan 31, 201914178780 - (D) (P.T.A.B. Jan. 31, 2019) Copy Citation UNITED STA TES p A TENT AND TRADEMARK OFFICE APPLICATION NO. FILING DATE 14/178,780 02/12/2014 530 7590 02/04/2019 LERNER, DAVID, LITTENBERG, KRUMHOLZ & MENTLIK 600 SOUTH A VENUE WEST WESTFIELD, NJ 07090 FIRST NAMED INVENTOR Tracee Eidenschink UNITED STATES DEPARTMENT OF COMMERCE United States Patent and Trademark Office Address: COMMISSIONER FOR PATENTS P.O. Box 1450 Alexandria, Virginia 22313-1450 www .uspto.gov ATTORNEY DOCKET NO. CONFIRMATION NO. STJUDE 3.0-201 1093 EXAMINER EASTWOOD, DAVID C ART UNIT PAPER NUMBER 3771 NOTIFICATION DATE DELIVERY MODE 02/04/2019 ELECTRONIC Please find below and/or attached an Office communication concerning this application or proceeding. The time period for reply, if any, is set in the attached communication. Notice of the Office communication was sent electronically on above-indicated "Notification Date" to the following e-mail address(es): eOfficeAction@ldlkm.com PTOL-90A (Rev. 04/07) UNITED STATES PATENT AND TRADEMARK OFFICE BEFORE THE PATENT TRIAL AND APPEAL BOARD Ex parte TRACEE EIDENSCHINK Appeal2018-000427 1 Application 14/178,780 Technology Center 3700 Before KEVIN F. TURNER, EDWARD A. BROWN, and LEE L. STEPINA, Administrative Patent Judges. STEPINA, Administrative Patent Judge. DECISION ON APPEAL STATEMENT OF THE CASE Appellant appeals under 35 U.S.C. § 134(a) from the Examiner's decision to reject claims 1---6, 8, 9, 13, and 16-19. 2 We have jurisdiction under 35 U.S.C. § 6(b ). We AFFIRM. 1 St. Jude Medical, Cardiology Division, Inc. is the Appellant and is listed in the Appeal Brief as the real party in interest. Appeal Br. 2. 2 Claims 7, 10-12, 14, and 15 are withdrawn. Appeal Br. 10-11 (Claims App.). Appeal2018-000427 Application 14/178,780 CLAIMED SUBJECT MATTER The claims are directed to a system and method for filtering and removing debris from the bloodstream of a patient. Spec. ,r 2. Claims 1 and 18, reproduced below with emphases added, are illustrative of the claimed subject matter: 1. A vessel protector, comprising: a body formed from a filtering material, the body having a collapsed configuration and a tubular expanded configuration with an open proximal end and an open distal end, and having openings of a size no smaller than about 80 um2 and no larger than about 3 00 um2; a first snare attached to one end of the body; and a first pull-wire connected to the first snare, whereby the exertion of a pulling force on the first pull-wire contracts the first snare and thereby closes the one end of the body. Appeal Br. 10 (Claims App.). 3 18. A method for protecting blood vessels during a medical procedure, comprising: inserting a vessel protector system into a patient's body, the vessel protector system including a vessel protector and a sheath, the vessel protector having a body formed from a filtering material, the body having a collapsed configuration and a tubular expanded configuration, and having openings of a size no smaller than about 80 um2 and no larger than about 300 um2, and the sheath being movable relative to the body between a first position for holding the body in the collapsed configuration, and a second position for releasing the body for movement to the expanded configuration; positioning the vessel protector system adjacent an open end of at least one blood vessel; and moving the sheath to the second position to deploy the body, whereby the body moves to the tubular expanded configuration covering the open end of the at least one blood 3 Appellant uses the units "um" to indicate "µm" and "um2" to indicate "µm2.,, 2 Appeal2018-000427 Application 14/178,780 vessel to filter blood passing through the body into the at least one blood vessel. Id. at 12. REFERENCES The prior art relied upon by the Examiner in rejecting the claims on appeal is: Yodfat Sepetka Brady Greenberg Adams US 2003/0125801 Al July 3, 2003 US 6,663,650 B2 Dec. 16, 2003 US 2006/0276887 Al Dec. 7, 2006 US 2007 /0055365 Al Mar. 8, 2007 US 2014/0249568 Al Sept. 4, 2014 REJECTIONS I. Claims 1-6, 8, 9, 13, and 16-19 are rejected under 35 U.S.C. § 112, second paragraph, as indefinite. II. Claims 18 and 19 are rejected under 35 U.S.C. § I03(a) as unpatentable over Y odfat and Greenberg. III. Claims 18 and 19 are rejected under 35 U.S.C. § I03(a) as unpatentable over Adams and Greenberg. IV. Claims 1-6, 8, 9, 13, and 16 are rejected under 35 U.S.C. § I03(a) as unpatentable over Yodfat, Greenberg, and Brady. V. Claims 1-6, 8, 9, 13, 16, and 17 are rejected under 35 U.S.C. § I03(a) as unpatentable over Adams, Greenberg, and Sepetka. OPINION Rejection I, Indefiniteness The Examiner determines that the term "about," as recited before the endpoints of the numerical ranges in each of independent claims 1, 16, and 18, renders these claims indefinite. See Final Act. 7-8. Specifically, the Examiner states, "the instant specification fails to disclose with sufficient 3 Appeal2018-000427 Application 14/178,780 specificity the degree to which the term 'about' should be afforded." Id. The Examiner likens claims 1, 16, and 18 to claims that were determined to be indefinite in Amgen, Inc. v. Chugai Pharm Co., Ltd., 927 F.2d 1200 (Fed. Cir. 1991). Id. at3--4. Appellant contends "one of ordinary skill in the art would know that the claims' recitation of 'about' in the terms 'about 80 um2 ' and 'about 300 um2 ' is intended to account for the manufacturing variation, or 'tolerance,' in the size of the openings," and "infringement of the claims could be clearly determined by measuring the size of the openings of an accused device." Appeal Br. 5. Appellant asserts that the term "about" as recited in the independent claims merely reflects the practicalities of manufacturing a filter material, and, in the context of the recited limitations, a person of ordinary skill in the art would understand this. Id. at 6. In response, the Examiner finds that Greenberg qualifies as "close prior art" as discussed in Amgen, and, therefore, given the lack of guidance provided by the Specification as to the meaning of the term "about" in claims 1, 16, and 18, these claims are properly rejected as indefinite. Ans. 4--5; see also Amgen, 927 F.2d at 1218. Appellant has the better position. The decision in Amgen included an explicit caution that the holding therein "should not be understood as ruling out any and all uses of [the term 'about'] in patent claims. It may be acceptable in appropriate fact situations ... even though it is not here." Amgen, 927 F.2d at 1218. The Court also indicated that even without the use of the term "about," the claims at issue were indefinite. Id. at 1218. The Court's cautionary language highlights that the determination of indefiniteness based on the use of the word "about" is to be based on the facts presented in each case. In Amgen, the two principal factors that the 4 Appeal2018-000427 Application 14/178,780 Court found probative were that the only available method to measure the "specific activity" that was claimed using the term of degree "about" was itself an imprecise form of measurement and that the term "about" was a significant factor in the patentee's ability to obtain allowance of the claims at issue over the prior art. Id. at 1217-1218. Here, the cross-sectional areas of the pores of the filter material are readily susceptible of being accurately measured by any number of methods inasmuch as they relate to physical dimensions of the pores. Further, as will be seen in the ensuing discussion of the rejections based on the prior art, the claimed size of the openings is not critical to the patentability of the claims. As such, the outcome in Amgen is not particularly germane to the present situation. For these reasons, we do not sustain this rejection. Rejection II, Yodfat and Greenberg (a) The Examiner relies on Y odfat to teach many of the elements recited in claim 18, but relies on Greenberg to teach that, in a blood filtering element, a "pore diameter should be at least 1 Oµm and preferably 20µm in diameter ... which would provide an open size range of 78.5 µm2-3 l 4 µm2." Final Act. 9-10; see also Greenberg ,r 5. Further, the Examiner determines that "[i]t would have been obvious to ... provide the filtering deflecting means of Adams with the open size range as disclosed by Greenberg since Greenberg discloses that this opening size is preferable for allowing blood flow while preventing the passage of clots and emboli (paragraph 5)." Final Act. 10-11. Appellant argues that the Examiner erred in finding that Greenberg discloses that the size of the pores in its filter media are preferably 20 µm in 5 Appeal2018-000427 Application 14/178,780 diameter. Appeal Br. 8. Specifically, Appellant asserts, "Greenberg's paragraph [0005] does not disclose 'openings of a size ... no larger than about 300 um2,' but rather, discloses pores of at least 10 um in diameter (area of78.5 um2) or pores of at least 20 um in diameter (area of314 um2)." Id. In response, the Examiner states: Greenberg teaches pores that encompass the disclosed range of between about 80µm2 and about 300µm2 which corresponds to no smaller than about 80µm2 and no larger than about 300µm2 by teaching "pores of at least 10 µmin diameter ( area of 78.5 µm2)" which discloses openings which are no smaller than about 80µm2 and no larger than about 300µm2. Ans. 9 (emphasis omitted). Thus, the Examiner finds that Greenberg's disclosure of pores having diameters ofat least 10 µm (areas of at least 78.5 µm2) satisfies the pore size requirement in claim 18 because this disclosure teaches pore sizes falling within (as well as above) the recited 80 µm2-300 µm2 range. Accordingly, the Examiner implicitly interprets claim 18 as allowing for pore sizes to also exceed the 3 00 µm2 upper limit of the range. In reply, Appellant contends that the range of pore sizes set forth in claim 18 applies to all the pores in the filter material, i.e., that the filter material does not allow passage of particles larger than the 300 µm2 upper limit. See Reply Br. 1-3. Consequently, according to Appellant, the disclosure in Greenberg of filter material having pores with diameters of at least 10 µm (areas of at least 78.5 µm2) fails to meet the requirement that the pores have openings of a size no smaller than about 80 µm2 and no larger than about 300 µm2. See id. 6 Appeal2018-000427 Application 14/178,780 During examination of a patent application, pending claims are given their broadest reasonable construction consistent with the Specification. In re Am. Acad. of Sci. Tech Ctr., 367 F.3d 1359, 1364 (Fed. Cir. 2004). The correct inquiry in giving a claim term its broadest reasonable interpretation in light of the specification is not whether the specification proscribes or precludes some broad reading of the claim term adopted by the examiner. And it is not simply an interpretation that is not inconsistent with the specification. It is an interpretation that corresponds with what and how the inventor describes his invention in the specification, i.e., an interpretation that is "consistent with the specification." In re Smith Int'!, Inc., 871 F.3d 1375, 1382-1383 (Fed. Cir. 2017) (quoting In re Morris, 127 F.3d 1048, 1054 (Fed. Cir. 1997)). Claim 18 recites a method for protecting blood vessels during a medical procedure. Appeal Br. 12 (Claims App.). Paragraphs 20 and 21 of the Specification describe accomplishing this function by blocking particulates that are greater than a certain size while allowing the passage of blood, and paragraph 21 explains that openings in the filter material having a size of "between about 80 µm2 and 300 µm2" perform this function. This discussion in paragraph 21 is the only place in the Specification that mentions the recited 80 µm2-300 µm2 pore size range. Accordingly, the broadest reasonable interpretation of claim 18, consistent with the Specification, precludes using a filter material having pore sizes greater than 300 µm2 inasmuch as the purpose of the filter material is to block particulate, and having pore sizes larger than 300 µm2 would, by passing relatively large particles, frustrate the blocking effect of having pores with sizes inside the recited range. Consequently, the Examiner's finding that Greenberg's disclosure of pores having diameters of at least 10 µm (areas of at least 78.5 µm2) satisfies the pore size requirement in claim 18 is based on an unreasonably broad interpretation of claim 18. 7 Appeal2018-000427 Application 14/178,780 (b) The Examiner provides an alternate basis for rejecting claim 18, namely, that in light of the teachings of Yodfat and Greenberg, a person of ordinary skill in the art would have recognized the size of pores in a filter material as a result-effective variable. Final Act. 11. Specifically, the Examiner finds Greenberg teaches open pore sizes may be in the recited range "for the purpose of preventing the passage of clots and emboli." Id. ( citing Greenberg ,r 5). From this, the Examiner determines that it would have been obvious to a person of ordinary skill in the art, as a matter of routine optimization, "to provide the openings of a size no smaller than about 80 µm2 and no larger than about 300 µm2, for the purpose of preventing the passage of clots and emboli." Id. (citing In re Aller, 220 F.2d 454 (CCPA 1955)). Appellant does not specifically discuss the Examiner's alternate basis for rejecting claim 18. See Appeal Br. 7-9; Reply Br. 1-3. However, Appellant asserts that Greenberg teaches away from providing an upper limit of 300 µm2 by disclosing that a pore diameter of at least 20 µm (an area of 314 µm2) is preferred. Appeal Br. 8. Appellant contends that this disclosure in Greenberg encourages the use of pore sizes of 314 µm2 and above, and, therefore, discourages the use of pore sizes of less than 314 µm2. Reply Br. 2-3. The Examiner's finding that Greenberg teaches that the size of pores in filter material is recognized as a result-effective variable for blood filtering (Final Act. 11) is supported by a preponderance of the evidence. See Greenberg, Abstract, ,r 5. Further, Appellant's argument that Greenberg teaches away from the pore size range recited in claim 18 is unavailing. See In re Fulton, 391 F.3d 1195, 1200 (Fed. Cir. 2004) ("[A] finding that the 8 Appeal2018-000427 Application 14/178,780 prior art as a whole suggests the desirability of a particular combination need not be supported by a finding that the prior art suggests that the combination claimed ... is the preferred, or most desirable, combination."). The statement in Greenberg that a pore diameter of at least 20 µm ( area of at least 314 µm2) is preferred, but also indicating that pore diameters of at least 10 µm (areas of at least 78.5 µm2) function to filter blood (Greenberg ,r 5), does not amount to teaching away from the use of pore diameters sizes limited to a range of 80 µm2 to 300 µm2 as recited. Accordingly, we sustain the Examiner's rejection of claim 18, and claim 19 depending therefrom, as unpatentable over Y odfat and Greenberg. Rejections 111-V The Examiner relies on the same findings of fact and reasoning regarding modifications based on Greenberg in Rejections III-Vas discussed above for Rejection II. See Final Act. 13-16, 20-22. Appellant contends that the arguments discussed above apply to each of Rejections HI- V and makes no separate arguments contesting any of these rejections. See Appeal Br. 7-9. Accordingly, for the same reasons discussed regarding Rejection II, we sustain Rejections III-V. DECISION The Examiner's decision rejecting claims 1-6, 8, 9, 13, and 16-19 is affirmed. No time period for taking any subsequent action in connection with this appeal may be extended under 37 C.F.R. § 1.136(a). AFFIRMED 9 Copy with citationCopy as parenthetical citation