Current through Register Vol. 63, No. 11, November 1, 2024
Section 690-240-0440 - Additional Standards for Artesian Monitoring Wells(1) Monitoring wells penetrating into an artesian aquifer shall have an upper oversize drillhole at least four inches greater in diameter than the nominal diameter of the permanent well casing except as noted in OAR 690-240-0525 concerning piezometers. Watertight unperforated casing shall extend and be sealed, according to OAR 690-240-0475, at least five feet into the confining interval immediately overlying the artesian water-bearing zone. (2) If an artesian monitoring well flows at land surface, the well shall be equipped with a control valve and a watertight mechanical cap, threaded or welded, so that all flow of water from the well can be completely stopped. (3) All flowing artesian monitoring wells shall be equipped with a pressure gauge placed on a dead-end line. A petcock valve shall be placed between the gauge and well casing. (4) All flowing artesian monitoring wells shall be tested for artesian shut-in pressure in pounds per square inch and rate of flow in cubic feet per second, or gallons per minute, under free discharge conditions. This data shall be reported on the well report. Or. Admin. Code § 690-240-0440
WRD 8-1993, f. 12-14-93, cert. ef. 1-1-94; WRD 2-1995, f. 5-17-95, cert. ef. 7-1-95; WRD 7-2001, f. & cert. ef. 11-15-01; WRD 1-2003, f. & cert. ef. 3-14-03, Renumbered from 690-240-0118; WRD 5-2016, f. & cert. ef. 9/6/2016Stat. Auth.: ORS 536.090 & 537.505 - 537.795
Stats. Implemented: ORS 536.090 & 537.505 - 537.795