Current through November 8, 2024
Section 705.177 - Alongside tracks at short-line and branch-line turnouts and certain power-operated turnouts1. Walkways alongside tracks at short-line and branch-line turnouts and, except as otherwise provided in NAC 705.181, at all power-operated turnouts, in addition to the requirements of NAC 705.160, must:(a) Be present on the switch stand side of the track from not less than 50 feet ahead of the switch stand to not less than the 12-foot-6-inch clearance point behind the switch stand;(b) If 10 feet or more from the switch stand, be not less than 5 feet in width;(c) If less than 10 feet, but more than 4 feet from the switch stand:(1) Be not less than 5 feet in width;(2) Have a straight outer edge; and(3) Occupy a total area of not less than 39 square feet; and(d) If 4 feet or less from the switch stand, be not less than 3 feet in width.Nev. Admin. Code § 705.177
Added to NAC by Pub. Utilities Comm'n by R051-01, eff. 12-17-2001NRS 703.1545, 704.280, 704.307